Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Ventilation system, Bürohaus Fribourg [CH], per 1 p. EF v3.1 climate change 2.640e+05 kg CO2 eq (Monte Carlo 95 % interval 2.549e+05–3.185e+05). Main contributors: Ventilation duct, steel, zinc coated, s= 0.75mm, at plant 13 %; Ventilation system, Bürohaus Fribourg, various components 13 %; Ventilation duct, steel, zinc coated, s= 0.87mm, at plant 12 %; Ventilation duct, steel, zinc coated, s= 1.0mm, at plant 10 %; Ventilation unit 13000 m3/h, w. rotary heat exchanger, at pl… 7 %; Ventilation system, Bürohaus Fribourg, special components 6 %. Status: final control passed.
Item Value
Dataset name Ventilation system, Bürohaus Fribourg
Dataset UUID / graph id c4e07610-8363-3ecf-b332-006b66f3ae79 / activity:ventilation_system_bürohaus_fribourg__ch
Reference product, unit Ventilation system, Bürohaus Fribourg, 1 p
Location CH
Time period 2014-01/2014-12
Category ventilation / production of components
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

Production of a ventilation system for an office building with offices, common rooms, kitchen, restaurant, auditorium and car park. The inventory is based on a building with a total heated gross floor area of 10161 m2 and a total nominal air flow of 54400 m3/h, total weight of the components: 15755 kg/Unit, building with a specific air flow rate of 5.4 m3/h per m2 heated gross floor area. Data from call of bid including components for air handling units, ducts including insulation, air valves, roof-hoods, dampers, fire dampers, silencers. The data represent a ductwork mainly made of galvanized steel and includes air handling units mainly with heat recovery. System with central air handling units. Building without ground heat exchanger.; UUID: c4e07610-8363-3ecf-b332-006b66f3ae79

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 p of Ventilation system, Bürohaus Fribourg (CH). All results are given per unit of the reference flow.

System boundary

Materials used for the production. Energy use for the different production steps and for heating the production building. Transport of raw materials to the plant. Estimation for infrastructure of the production site included.

Technology

Technology, materials and components used for ventilation systems in commercial and public buildings

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Ventilation duct, steel, zinc coated, s= 0.75mm, at plant technosphere CH 1402.1 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 13.3 ███
Ventilation system, Bürohaus Fribourg, various components technosphere CH 1 p lognormal, GSD² 1.24 (2,4,1,1,1,5) 13.2 ███
Ventilation duct, steel, zinc coated, s= 0.87mm, at plant technosphere CH 1102.6 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 11.8 ██
Ventilation duct, steel, zinc coated, s= 1.0mm, at plant technosphere CH 791.4 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 9.6 ██
Ventilation unit 13000 m3/h, w. rotary heat exchanger, at plant technosphere CH 1.1 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 7.5 █
Ventilation system, Bürohaus Fribourg, special components technosphere CH 1 p lognormal, GSD² 1.24 (2,4,1,1,1,5) 5.7 █
Ventilation unit 6700 m3/h, w. circuit connected heat exchanger, at plant technosphere CH 1.567 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 5.3 █
Ventilation duct, steel, zinc coated, s= 0.62mm, at plant technosphere CH 548.52 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 4.2 █
Ventilation unit 13000 m3/h, w. cross plate heat excanger, at plant technosphere CH 0.546 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 4.2 █
Ventilation unit 3500 m3/h, w. cross plate heat excanger, at plant technosphere CH 1.486 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 4.0 █
Ventilation unit 6700 m3/h, w. cross plate heat excanger, at plant technosphere CH 0.896 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 3.9 █
Spiral-seam duct, steel, zinc coated, s= 0.5mm, at plant technosphere CH 563.78 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 3.2 █
Ventilation duct, steel, zinc coated, s= 1.25mm, at plant technosphere CH 210.68 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 3.1 █
Silencer for ventilator unit 13000 m3/h, modular, at plant technosphere CH 8.122 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 2.3 ·
Silencer for ventilator unit 6700 m3/h, modular, at plant, Device technosphere CH 9.852 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 1.8 ·
EI 60 fire insulation, 70mm, 120kg/m3, reinforced alumium foil, at plant technosphere CH 364 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 1.7 ·
Ventilator unit 13000 m3/h, modular, w. filter, without silencer, at plant technosphere CH 0.769 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 1.3 ·
Spiral-seam duct, steel, zinc coated, s= 0.6mm, at plant technosphere CH 181.73 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 1.2 ·
Silencer for ventilator unit 3500 m3/h, modular, at plant technosphere CH 5.944 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 0.8 ·
Thermal insulation, 30mm, 40kg/m3, reinforced alumium foil, at plant technosphere CH 374 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.6 ·
Flexible duct, aluminum/PET, DN of 125, at plant technosphere RER 1434.4 m lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.5 ·
Spiral-seam duct, stainless steel, s= 0.8mm, at plant technosphere CH 32.044 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.4 ·
Spiral-seam duct, steel, zinc coated, s= 0.8mm, at plant technosphere CH 15.368 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.1 ·
Spiral-seam duct, stainless steel, s= 0.5mm, at plant technosphere CH 12.818 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.1 ·
Ventilation duct, stainless steel, s= 1.0mm, at plant technosphere CH 3.4234 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.1 ·
Ventilation duct, stainless steel, s= 0.87mm, at plant technosphere CH 1.68 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.0 ·
Ventilation duct, stainless steel, s= 0.62mm, at plant technosphere CH 0.175 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.0 ·

Data quality

27 of 27 direct exchanges carry a declared pedigree, 27 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.33 · completeness 4.0 · temporal 1.0 · geographical 1.0 · technological 1.0 · sample size 5.0.

Field As declared by the publisher
Data generator / entry / validation data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Alex Primas (HSLU)
extrapolations none
sampling procedure Data from call of bids for a ventilation system of a specific building used. Data completed with information from literature and from manufacturers
production volume na
uncertainty adjustments none
time period comment Amount of material investigated in 2013. Process information partly from 2003 to 2012

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 3749 2432 7008 1.75
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 990.2 673.4 2143 1.77
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 2.629e+05 2.533e+05 3.175e+05 1.12
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 135.2 112.2 225.7 1.44
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 2.640e+05 2.549e+05 3.185e+05 1.12
EF-particulate Matter Impact on human health disease incidence 0.04105 0.03078 0.06829 1.5
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 1.251e+06 1.230e+06 2.140e+06 1.33
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 2.386e+04 2.328e+04 4.428e+04 1.5
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 1.275e+06 1.260e+06 2.170e+06 1.33
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 289.1 257.2 428.2 1.3
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 151.9 112.5 677.4 2.52
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 1.463e+04 8588 2.878e+04 1.89
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.449e-04 1.443e-04 3.524e-04 1.57
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 1.114e-04 9.480e-05 2.020e-04 1.47
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 2.562e-04 2.586e-04 5.054e-04 1.4
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 0.01058 0.009614 0.02797 1.73
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 3.970e-04 2.882e-04 7.821e-04 1.67
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 0.01098 0.009955 0.02848 1.71
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 7.19e+04 2.645e+04 4.337e+05 4.29
Land use Soil quality index pt (soil quality index) 1.340e+06 1.299e+06 2.178e+06 1.3
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 0.007435 0.006636 0.01204 1.35
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 778.3 742.3 1256 1.31
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 3.074e+06 2.943e+06 4.329e+06 1.21
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 6.256 -6.529 30.11 —
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 3.458e+04 -5.109e+07 2.502e+07 —

Climate change 2.640e+05 kg CO2 eq per p. Main contributors: Ventilation duct, steel, zinc coated, s= 0.75mm, at plant 13 %; Ventilation system, Bürohaus Fribourg, various components 13 %; Ventilation duct, steel, zinc coated, s= 0.87mm, at plant 12 %; Ventilation duct, steel, zinc coated, s= 1.0mm, at plant 10 %; Ventilation unit 13000 m3/h, w. rotary heat exchanger, at pl… 7 %; Ventilation system, Bürohaus Fribourg, special components 6 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Ventilation duct, steel, zinc coated, s= 0.75mm, at plant 13 %; Ventilation system, Bürohaus Fribourg, various components 13 %; Ventilation duct, steel, zinc coated, s= 0.87mm, at plant 12 %; Ventilation duct, steel, zinc coated, s= 1.0mm, at plant 10 %; Ventilation unit 13000 m3/h, w. rotary heat exchanger, at pl… 7 %; Ventilation system, Bürohaus Fribourg, special components 6 %. Most sensitive exchanges (Section 6.3): Ventilation duct, steel, zinc coated, s= 0.75mm, at plant [CH] (-2.5 / +3.1 %); Ventilation system, Bürohaus Fribourg, various components [CH] (-2.5 / +3.1 %); Ventilation duct, steel, zinc coated, s= 0.87mm, at plant [CH] (-2.3 / +2.8 %).

Independent recalculation

The publisher publishes no LCIA result for this dataset; the closure check of Section 7 is the recalculation test.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Ventilation duct, steel, zinc coated, s= 0.75mm, at plant [CH] 1402 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -2.5 / +3.1 4.5 (Eutrophication, terrestrial)
Ventilation system, Bürohaus Fribourg, various components [CH] 1 p ×0.81 / ×1.23 lognormal, GSD² 1.24 -2.5 / +3.1 3.5 (Climate change-Biogenic)
Ventilation duct, steel, zinc coated, s= 0.87mm, at plant [CH] 1103 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -2.3 / +2.8 3.6 (Eutrophication, terrestrial)
Ventilation duct, steel, zinc coated, s= 1.0mm, at plant [CH] 791.4 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -1.8 / +2.2 2.6 (Eutrophication, terrestrial)
Ventilation unit 13000 m3/h, w. rotary heat exchanger, at plant [CH] 1.1 p ×0.797 / ×1.25 lognormal, GSD² 1.26 -1.5 / +1.9 3.4 (Resource use, minerals and metals)
Ventilation system, Bürohaus Fribourg, special components [CH] 1 p ×0.81 / ×1.23 lognormal, GSD² 1.24 -1.1 / +1.3 1.8 (Resource use, minerals and metals)
Ventilation unit 6700 m3/h, w. circuit connected heat exchanger, at plant [CH] 1.567 p ×0.797 / ×1.25 lognormal, GSD² 1.26 -1.1 / +1.3 3.7 (Eutrophication, freshwater)
Ventilation unit 13000 m3/h, w. cross plate heat excanger, at plant [CH] 0.546 p ×0.797 / ×1.25 lognormal, GSD² 1.26 -0.8 / +1.1 1.7 (Resource use, minerals and metals)
Ventilation unit 3500 m3/h, w. cross plate heat excanger, at plant [CH] 1.486 p ×0.797 / ×1.25 lognormal, GSD² 1.26 -0.8 / +1.0 1.4 (Ecotoxicity, freshwater_organics)
Ventilation unit 6700 m3/h, w. cross plate heat excanger, at plant [CH] 0.896 p ×0.797 / ×1.25 lognormal, GSD² 1.26 -0.8 / +1.0 1.5 (Eutrophication, freshwater)
Ventilation duct, steel, zinc coated, s= 0.62mm, at plant [CH] 548.5 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.8 / +1.0 1.7 (Eutrophication, terrestrial)
Spiral-seam duct, steel, zinc coated, s= 0.5mm, at plant [CH] 563.8 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.6 / +0.8 1.5 (Eutrophication, terrestrial)
Ventilation duct, steel, zinc coated, s= 1.25mm, at plant [CH] 210.7 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.6 / +0.7 0.8 (Human toxicity, cancer_organics)
Silencer for ventilator unit 13000 m3/h, modular, at plant [CH] 8.122 p ×0.797 / ×1.25 lognormal, GSD² 1.26 -0.5 / +0.6 0.7 (Ecotoxicity, freshwater_organics)
Silencer for ventilator unit 6700 m3/h, modular, at plant, Device [CH] 9.852 p ×0.797 / ×1.25 lognormal, GSD² 1.26 -0.4 / +0.5 0.6 (Ecotoxicity, freshwater_inorganics)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 2.640e+05 kg CO2 eq per p (95 % interval 2.549e+05–3.185e+05). Dominant contributors: Ventilation duct, steel, zinc coated, s= 0.75mm, at plant 13 %; Ventilation system, Bürohaus Fribourg, various components 13 %; Ventilation duct, steel, zinc coated, s= 0.87mm, at plant 12 %; Ventilation duct, steel, zinc coated, s= 1.0mm, at plant 10 %; Ventilation unit 13000 m3/h, w. rotary heat exchanger, at pl… 7 %; Ventilation system, Bürohaus Fribourg, special components 6 %. Most sensitive: Ventilation duct, steel, zinc coated, s= 0.75mm, at plant [CH] (-2.5 / +3.1 %); Ventilation system, Bürohaus Fribourg, various components [CH] (-2.5 / +3.1 %); Ventilation duct, steel, zinc coated, s= 0.87mm, at plant [CH] (-2.3 / +2.8 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 p
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 3.5e-16
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 27/27 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 2.640e+05 in [2.549e+05, 3.185e+05]
time period declared PASS 2014-01/2014-12
geography is a known location code PASS CH
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Klingler M., Kasser U., Savi D., Primas A., Stettler Y., Gujer P. (2014) Ökobilanzdaten für Lüftungs- und Wärmeanlagen. Schlussbericht, BFE. Bundesamt für Energie (BFE). Bern. Type: Separate publication Source: Report First author: Klingler M. Other authors: Kasser U., Savi D., Primas A., Stettler Y., Gujer P. Year: 2014 Title of anthology: Schlussbericht, BFE Place of publication: Bern Publisher:… — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use