OpenData Wiki

Dataset documentation and review before publication

User Tools

Site Tools


datasets:bafu:c7182cef-98b3-3577-9c17-829665d9d1f1

Ventilation system, Geschäftshaus B, Esslingen — CH

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Ventilation system, Geschäftshaus B, Esslingen [CH], per 1 p. EF v3.1 climate change 3.528e+04 kg CO2 eq (Monte Carlo 95 % interval 3.351e+04–4.304e+04). Main contributors: Ventilation unit 13000 m3/h, w. rotary heat exchanger, at pl… 32 %; Ventilation duct, steel, zinc coated, s= 0.75mm, at plant 18 %; Ventilation duct, steel, zinc coated, s= 0.62mm, at plant 15 %; EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium fo… 7 %; Ventilation duct, steel, zinc coated, s= 0.87mm, at plant 7 %; Silencer for ventilator unit 13000 m3/h, modular, at plant 5 %. Status: final control passed.
Item Value
Dataset name Ventilation system, Geschäftshaus B, Esslingen
Dataset UUID / graph id c7182cef-98b3-3577-9c17-829665d9d1f1 / activity:ventilation_system_geschäftshaus_b_esslingen__ch
Reference product, unit Ventilation system, Geschäftshaus B, Esslingen, 1 p
Location CH
Time period 2014-01/2014-12
Category ventilation / production of components
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

Production of a ventilation system for an office building with offices only (no kitchen, restaurant or car park). The inventory is based on a building with a total heated gross floor area of 2472 m2 and a total nominal air flow of 5700 m3/h, total weight of the components: 2815 kg/Unit, building with a specific air flow rate of 2.3 m3/h per m2 heated gross floor area. Data from call of bid including components for air handling units, ducts including insulation, air valves, roof-hoods, dampers, fire dampers, silencers. The data represent a ductwork mainly made of galvanized steel and includes air handling units mainly with heat recovery. System with central air handling units.Ground heat exchanger of building not included (is part of the concrete construction).; UUID: c7182cef-98b3-3577-9c17-829665d9d1f1

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 p of Ventilation system, Geschäftshaus B, Esslingen (CH). All results are given per unit of the reference flow.

System boundary

Materials used for the production. Energy use for the different production steps and for heating the production building. Transport of raw materials to the plant. Estimation for infrastructure of the production site included.

Technology

Technology, materials and components used for ventilation systems in commercial and public buildings

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Ventilation unit 13000 m3/h, w. rotary heat exchanger, at plant technosphere CH 0.626 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 31.9 ██████
Ventilation duct, steel, zinc coated, s= 0.75mm, at plant technosphere CH 257.03 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 18.2 ████
Ventilation duct, steel, zinc coated, s= 0.62mm, at plant technosphere CH 255.27 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 14.6 ███
EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium foil, at plant technosphere CH 266.33 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 7.4 █
Ventilation duct, steel, zinc coated, s= 0.87mm, at plant technosphere CH 86.406 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 6.9 █
Silencer for ventilator unit 13000 m3/h, modular, at plant technosphere CH 2.504 p lognormal, GSD² 1.26 (3,4,1,1,1,5) 5.4 █
Ventilation system, Geschäftshaus B, Esslingen, various components technosphere CH 1 p lognormal, GSD² 1.24 (2,4,1,1,1,5) 4.1 █
Spiral-seam duct, steel, zinc coated, s= 0.5mm, at plant technosphere CH 84.933 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 3.6 █
Spiral-seam duct, steel, zinc coated, s= 0.6mm, at plant technosphere CH 53.7 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 2.7 █
Ventilation duct, steel, zinc coated, s= 1.0mm, at plant technosphere CH 23.774 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 2.2 ·
Spiral-seam duct, steel, zinc coated, s= 0.8mm, at plant technosphere CH 28.054 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 1.8 ·
Thermal insulation, 60mm, 40kg/m3, reinforced alumium foil, at plant technosphere CH 58.852 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.9 ·
Ventilation duct, stainless steel, s= 0.62mm, at plant technosphere CH 3.5 m2 lognormal, GSD² 1.24 (2,4,1,1,1,5) 0.3 ·

Data quality

13 of 13 direct exchanges carry a declared pedigree, 13 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.15 · completeness 4.0 · temporal 1.0 · geographical 1.0 · technological 1.0 · sample size 5.0.

Field As declared by the publisher
Data generator / entry / validation data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Alex Primas (HSLU)
extrapolations none
sampling procedure Data from call of bids for a ventilation system of a specific building used. Data completed with information from literature and from manufacturers
production volume na
uncertainty adjustments none
time period comment Amount of material investigated in 2013. Process information partly from 2003 to 2012

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 506.8 327 972.7 1.75
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 129.2 89.03 281.8 1.77
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 3.513e+04 3.335e+04 4.285e+04 1.14
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 17.34 14.21 28.41 1.44
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 3.528e+04 3.351e+04 4.304e+04 1.14
EF-particulate Matter Impact on human health disease incidence 0.005478 0.004087 0.009289 1.51
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 1.701e+05 1.629e+05 2.928e+05 1.35
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 3935 3607 7666 1.6
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 1.741e+05 1.682e+05 2.981e+05 1.35
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 39.11 34.27 58.35 1.3
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 20.37 14.82 93.99 2.52
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 1985 1166 4070 1.89
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.983e-05 1.907e-05 4.751e-05 1.56
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 1.485e-05 1.274e-05 2.606e-05 1.45
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 3.469e-05 3.428e-05 6.623e-05 1.39
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 0.001368 0.001217 0.003602 1.72
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 5.176e-05 3.604e-05 1.032e-04 1.68
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 0.00142 0.001268 0.003666 1.7
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 9671 3416 6.018e+04 4.3
Land use Soil quality index pt (soil quality index) 1.788e+05 1.700e+05 2.908e+05 1.31
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 0.001017 8.881e-04 0.001656 1.36
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 105 98.48 163.4 1.29
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 4.262e+05 4.011e+05 6.011e+05 1.23
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 0.8638 -0.74 3.975 —
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 4467 -7.554e+06 3.772e+06 —

Climate change 3.528e+04 kg CO2 eq per p. Main contributors: Ventilation unit 13000 m3/h, w. rotary heat exchanger, at pl… 32 %; Ventilation duct, steel, zinc coated, s= 0.75mm, at plant 18 %; Ventilation duct, steel, zinc coated, s= 0.62mm, at plant 15 %; EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium fo… 7 %; Ventilation duct, steel, zinc coated, s= 0.87mm, at plant 7 %; Silencer for ventilator unit 13000 m3/h, modular, at plant 5 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Ventilation unit 13000 m3/h, w. rotary heat exchanger, at pl… 32 %; Ventilation duct, steel, zinc coated, s= 0.75mm, at plant 18 %; Ventilation duct, steel, zinc coated, s= 0.62mm, at plant 15 %; EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium fo… 7 %; Ventilation duct, steel, zinc coated, s= 0.87mm, at plant 7 %; Silencer for ventilator unit 13000 m3/h, modular, at plant 5 %. Most sensitive exchanges (Section 6.3): Ventilation unit 13000 m3/h, w. rotary heat exchanger, at plant [CH] (-6.5 / +8.1 %); Ventilation duct, steel, zinc coated, s= 0.75mm, at plant [CH] (-3.5 / +4.3 %); Ventilation duct, steel, zinc coated, s= 0.62mm, at plant [CH] (-2.8 / +3.4 %).

Independent recalculation

The publisher publishes no LCIA result for this dataset; the closure check of Section 7 is the recalculation test.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Ventilation unit 13000 m3/h, w. rotary heat exchanger, at plant [CH] 0.626 p ×0.797 / ×1.25 lognormal, GSD² 1.26 -6.5 / +8.1 14.0 (Resource use, minerals and metals)
Ventilation duct, steel, zinc coated, s= 0.75mm, at plant [CH] 257 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -3.5 / +4.3 6.1 (Eutrophication, terrestrial)
Ventilation duct, steel, zinc coated, s= 0.62mm, at plant [CH] 255.3 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -2.8 / +3.4 5.9 (Eutrophication, terrestrial)
EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium foil, at plant [CH] 266.3 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -1.4 / +1.7 6.4 (Ecotoxicity, freshwater_organics)
Ventilation duct, steel, zinc coated, s= 0.87mm, at plant [CH] 86.41 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -1.3 / +1.6 2.1 (Eutrophication, terrestrial)
Silencer for ventilator unit 13000 m3/h, modular, at plant [CH] 2.504 p ×0.797 / ×1.25 lognormal, GSD² 1.26 -1.1 / +1.4 1.6 (Ecotoxicity, freshwater_inorganics)
Ventilation system, Geschäftshaus B, Esslingen, various components [CH] 1 p ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.8 / +1.0 1.5 (Human toxicity, cancer_inorganics)
Spiral-seam duct, steel, zinc coated, s= 0.5mm, at plant [CH] 84.93 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.7 / +0.9 1.7 (Eutrophication, terrestrial)
Spiral-seam duct, steel, zinc coated, s= 0.6mm, at plant [CH] 53.7 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.5 / +0.6 1.1 (Eutrophication, terrestrial)
Ventilation duct, steel, zinc coated, s= 1.0mm, at plant [CH] 23.77 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.4 / +0.5 0.6 (Climate change-Land use and land use change)
Spiral-seam duct, steel, zinc coated, s= 0.8mm, at plant [CH] 28.05 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.3 / +0.4 0.6 (Eutrophication, terrestrial)
Thermal insulation, 60mm, 40kg/m3, reinforced alumium foil, at plant [CH] 58.85 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.2 / +0.2 0.6 (Ecotoxicity, freshwater_organics)
Ventilation duct, stainless steel, s= 0.62mm, at plant [CH] 3.5 m2 ×0.81 / ×1.23 lognormal, GSD² 1.24 -0.1 / +0.1 0.1 (Human toxicity, cancer_inorganics)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 3.528e+04 kg CO2 eq per p (95 % interval 3.351e+04–4.304e+04). Dominant contributors: Ventilation unit 13000 m3/h, w. rotary heat exchanger, at pl… 32 %; Ventilation duct, steel, zinc coated, s= 0.75mm, at plant 18 %; Ventilation duct, steel, zinc coated, s= 0.62mm, at plant 15 %; EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium fo… 7 %; Ventilation duct, steel, zinc coated, s= 0.87mm, at plant 7 %; Silencer for ventilator unit 13000 m3/h, modular, at plant 5 %. Most sensitive: Ventilation unit 13000 m3/h, w. rotary heat exchanger, at plant [CH] (-6.5 / +8.1 %); Ventilation duct, steel, zinc coated, s= 0.75mm, at plant [CH] (-3.5 / +4.3 %); Ventilation duct, steel, zinc coated, s= 0.62mm, at plant [CH] (-2.8 / +3.4 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 p
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 3.5e-16
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 13/13 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 3.528e+04 in [3.351e+04, 4.304e+04]
time period declared PASS 2014-01/2014-12
geography is a known location code PASS CH
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Klingler M., Kasser U., Savi D., Primas A., Stettler Y., Gujer P. (2014) Ökobilanzdaten für Lüftungs- und Wärmeanlagen. Schlussbericht, BFE. Bundesamt für Energie (BFE). Bern. Type: Separate publication Source: Report First author: Klingler M. Other authors: Kasser U., Savi D., Primas A., Stettler Y., Gujer P. Year: 2014 Title of anthology: Schlussbericht, BFE Place of publication: Bern Publisher:… — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use