OpenData Wiki

Dataset documentation and review before publication

User Tools

Site Tools


datasets:bafu:d1d1da4e-872e-31a3-9232-364044fde30f

Electricity, residual mix — CH

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Electricity, residual mix [CH], per 1 kWh. EF v3.1 climate change 0.0348 kg CO2 eq (Monte Carlo 95 % interval 0.03386–0.04877). Main contributors: Electricity, from natural gas 54 %; Electricity, nuclear, at power plant 19 %; Electricity, oil, at power plant 16 %; Electricity, at cogen 1MWth, wood chips, allocation exergy 7 %; Electricity, production mix photovoltaic, at plant 3 %. Status: final control passed.
Item Value
Dataset name Electricity, residual mix
Dataset UUID / graph id d1d1da4e-872e-31a3-9232-364044fde30f / activity:electricity_residual_mix__ch
Reference product, unit Electricity, residual mix, 1 kWh
Location CH — Data apply to untracked electricity supplied in Switzerland. Wind power plants are European averages.
Time period 2020/2020
Category electricity / supply mix
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

The location and technology of the production of the residual attributes have been for some technologies (biomass, solar, hydropower) adapted by the ENTSO-mix based on technologies, which is a rough estimation.; UUID:d1d1da4e-872e-31a3-9232-364044fde30f

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 kWh of Electricity, residual mix (CH). All results are given per unit of the reference flow.

System boundary

Includes the shares of residual attributes produced in Europe in 2019 with the different technologies. Not included are transformation, transport or distribution losses.

Technology

No technology description is provided because the dataset just describes the power plant portfolio of the respective country using current average technology per energy carrier.

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Electricity, from natural gas technosphere ENTSO-E 0.037506 kWh lognormal, GSD² 1.05 — 54.1 ███████████
Electricity, nuclear, at power plant technosphere UCTE 0.8296 kWh lognormal, GSD² 1.05 — 18.6 ████
Electricity, oil, at power plant technosphere UCTE 0.0058938 kWh lognormal, GSD² 1.05 — 16.4 ███
Electricity, at cogen 1MWth, wood chips, allocation exergy technosphere CH 0.0377 kWh lognormal, GSD² 1.05 — 6.8 █
Electricity, production mix photovoltaic, at plant technosphere DE 0.0328 kWh lognormal, GSD² 1.05 — 3.0 █
Electricity, hydropower, at reservoir power plant, non alpine regions technosphere RER 0.014336 kWh lognormal, GSD² 1.05 — 0.7 ·
Electricity, hydropower, at run-of-river power plant technosphere RER 0.027828 kWh lognormal, GSD² 1.05 — 0.3 ·
Electricity, hydropower, at reservoir power plant, alpine region technosphere RER 0.014336 kWh lognormal, GSD² 1.05 — 0.2 ·

Data quality

0 of 8 direct exchanges carry a declared pedigree, 8 carry a distribution.

Field As declared by the publisher
Data generator / entry / validation data generator: Rolf Frischknecht (TREEZE); data entry: Rolf Frischknecht (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE)
sampling procedure Statistical data
uncertainty adjustments none
validation details 10.05.2022
time period comment Time of publications.

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 8.250e-05 8.085e-05 1.151e-04 1.2
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 9.777e-05 8.061e-05 1.797e-04 1.52
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.03451 0.03361 0.04828 1.2
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 1.859e-04 1.015e-04 3.760e-04 1.93
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.0348 0.03386 0.04877 1.2
EF-particulate Matter Impact on human health disease incidence 7.280e-09 5.203e-09 1.254e-08 1.59
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.1245 0.1137 0.3392 1.77
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.00352 0.003264 0.008342 1.64
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.128 0.117 0.3465 1.76
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 7.786e-05 7.107e-05 1.027e-04 1.21
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 5.405e-06 4.657e-06 2.200e-05 2.21
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 3.746e-04 3.409e-04 5.208e-04 1.23
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 6.038e-12 6.381e-12 1.460e-11 1.51
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 5.738e-11 3.335e-11 1.042e-10 1.77
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 6.342e-11 4.278e-11 1.119e-10 1.65
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 4.046e-10 4.053e-10 9.903e-10 1.58
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 1.375e-11 1.327e-11 2.609e-11 1.41
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 4.183e-10 4.224e-10 1.008e-09 1.56
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 1.273 0.4283 7 4.26
Land use Soil quality index pt (soil quality index) 3.114 1.933 5.213 1.67
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 9.071e-09 5.686e-09 1.717e-08 1.77
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 1.570e-04 1.482e-04 2.391e-04 1.27
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 11.77 9.918 14.94 1.24
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 1.205e-07 1.157e-07 2.282e-07 1.41
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 0.1174 -83.76 42.21 —

Climate change 0.0348 kg CO2 eq per kWh. Main contributors: Electricity, from natural gas 54 %; Electricity, nuclear, at power plant 19 %; Electricity, oil, at power plant 16 %; Electricity, at cogen 1MWth, wood chips, allocation exergy 7 %; Electricity, production mix photovoltaic, at plant 3 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Electricity, from natural gas 54 %; Electricity, nuclear, at power plant 19 %; Electricity, oil, at power plant 16 %; Electricity, at cogen 1MWth, wood chips, allocation exergy 7 %; Electricity, production mix photovoltaic, at plant 3 %. Most sensitive exchanges (Section 6.3): Electricity, from natural gas [ENTSO-E] (-2.5 / +2.7 %); Electricity, nuclear, at power plant [UCTE] (-0.9 / +0.9 %); Electricity, oil, at power plant [UCTE] (-0.8 / +0.8 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh:

Category Graph Published Graph / published
Acidification 8.250e-05 1.646e-04 0.501
Climate change-Biogenic 9.777e-05 9.755e-05 1.002
Climate change-Fossil 0.03451 0.03445 1.002
Climate change-Land use and land use change 1.859e-04 1.858e-04 1.000
Climate change 0.0348 0.03474 1.002
EF-particulate Matter 7.280e-09 7.279e-09 1.000
Ecotoxicity, freshwater_inorganics 0.1245 0.1654 0.753
Ecotoxicity, freshwater_organics 0.00352 0.003392 1.038
Ecotoxicity, freshwater 0.128 0.1687 0.759
Eutrophication marine 7.786e-05 7.763e-05 1.003
Eutrophication, freshwater 5.405e-06 5.398e-06 1.001
Eutrophication, terrestrial 3.746e-04 4.722e-04 0.793
Human toxicity, cancer_inorganics 6.038e-12 4.956e-12 1.218
Human toxicity, cancer_organics 5.738e-11 5.737e-11 1.000
Human toxicity, cancer 6.342e-11 6.233e-11 1.018
Human toxicity, non-cancer_inorganics 4.046e-10 3.272e-10 1.236
Human toxicity, non-cancer_organics 1.375e-11 1.379e-11 0.997
Human toxicity, non-cancer 4.183e-10 3.410e-10 1.227
Ionising radiation, human health 1.273 1.273 1.000
Land use 3.114 2.513 1.239
Ozone depletion 9.071e-09 9.066e-09 1.001
Photochemical ozone formation - human health 1.570e-04 1.573e-04 0.998
Resource use, fossils 11.77 11.77 1.000
Resource use, minerals and metals 1.205e-07 1.171e-07 1.029
Water use 0.1174 0.1176 0.998
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 0.03473 kg CO2 eq; Ecological Scarcity
2021 total 636 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Electricity, from natural gas [ENTSO-E] 0.03751 kWh ×0.953 / ×1.05 lognormal, GSD² 1.05 -2.5 / +2.7 2.7 (Climate change-Fossil)
Electricity, nuclear, at power plant [UCTE] 0.8296 kWh ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.9 / +0.9 4.9 (Ionising radiation, human health)
Electricity, oil, at power plant [UCTE] 0.005894 kWh ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.8 / +0.8 0.9 (Photochemical ozone formation - human health)
Electricity, at cogen 1MWth, wood chips, allocation exergy [CH] 0.0377 kWh ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.3 / +0.3 4.7 (Land use)
Electricity, production mix photovoltaic, at plant [DE] 0.0328 kWh ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.1 / +0.1 3.1 (Resource use, minerals and metals)
Electricity, hydropower, at reservoir power plant, non alpine regions [RER] 0.01434 kWh ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.0 / +0.0 4.1 (Climate change-Land use and land use change)
Electricity, hydropower, at run-of-river power plant [RER] 0.02783 kWh ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.0 / +0.0 0.5 (Climate change-Biogenic)
Electricity, hydropower, at reservoir power plant, alpine region [RER] 0.01434 kWh ×0.953 / ×1.05 lognormal, GSD² 1.05 -0.0 / +0.0 0.5 (Climate change-Land use and land use change)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 0.0348 kg CO2 eq per kWh (95 % interval 0.03386–0.04877). Dominant contributors: Electricity, from natural gas 54 %; Electricity, nuclear, at power plant 19 %; Electricity, oil, at power plant 16 %; Electricity, at cogen 1MWth, wood chips, allocation exergy 7 %; Electricity, production mix photovoltaic, at plant 3 %. Most sensitive: Electricity, from natural gas [ENTSO-E] (-2.5 / +2.7 %); Electricity, nuclear, at power plant [UCTE] (-0.9 / +0.9 %); Electricity, oil, at power plant [UCTE] (-0.8 / +0.8 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 kWh
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 3.6e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) PASS graph / published = 1.002; categories within ±5 %: 17/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 8/8 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 0.0348 in [0.03386, 0.04877]
time period declared PASS 2020/2020
geography is a known location code PASS CH
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Frischknecht R. (2022) 2022 - Energy label for passenger cars - Frischknecht. treeze Ltd. — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.

datasets/bafu/d1d1da4e-872e-31a3-9232-364044fde30f.txt · Last modified: by 127.0.0.1