Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Electronic component, active, unspecified, at plant [GLO], per 1 kg. EF v3.1 climate change 457.2 kg CO2 eq (Monte Carlo 95 % interval 277.7–1016). Main contributors: Integrated circuit, IC, logic type, at plant 72 %; Integrated circuit, IC, memory type, at plant 23 %; Transistor, unspecified, at plant 3 %. Status: final control passed.
Item Value
Dataset name Electronic component, active, unspecified, at plant
Dataset UUID / graph id da6d0b4c-54ad-3388-8d07-38caeda40d00 / activity:electronic_component_active_unspecified_at_plant__glo
Reference product, unit Electronic component, active, unspecified, at plant, 1 kg
Location GLO — Data represent a global valuable average composition of active electronic components.
Time period 2023-01/2029-12
Category electronics / component
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

This module represents an unweighted average of all active components on a desktop motherboard, a laptop mainboard and a CRT TV board. In 2023, no major updates are implemented for this dataset, except for the use of updated ICT datasets in the background/inventory, e.g. capacitors, inductors, resistors, etc.; UUID: da6d0b4c-54ad-3388-8d07-38caeda40d00

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 kg of Electronic component, active, unspecified, at plant (GLO). All results are given per unit of the reference flow.

System boundary

This dataset covers material input (and within this the respective production efforts) for unspecified active electronic components.

Technology

see general comments

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Integrated circuit, IC, logic type, at plant technosphere GLO 0.55 kg lognormal, GSD² 2.33 — 72.4 ██████████████
Integrated circuit, IC, memory type, at plant technosphere GLO 0.309 kg lognormal, GSD² 2.33 — 23.5 █████
Transistor, unspecified, at plant technosphere GLO 0.117 kg lognormal, GSD² 2.33 — 3.2 █
Diode, unspecified, at plant technosphere GLO 0.0196 kg lognormal, GSD² 2.33 — 0.8 ·
Light emitting diode, LED, at plant technosphere GLO 0.00375 kg lognormal, GSD² 2.33 — 0.2 ·

Data quality

0 of 5 direct exchanges carry a declared pedigree, 5 carry a distribution.

Field As declared by the publisher
Data generator / entry / validation data generator: Lugas Raka Adrianto, Maulana Permana Ajie, Didier Beloin-Saint-Pierre (EMPA); data entry: Lugas Raka Adrianto, Maulana Permana Ajie, Didier Beloin-Saint-Pierre (EMPA); validation (proof reading): Mischa Zschokke (CARBOTECH)
extrapolations see Geography & Technology
sampling procedure Literature & own estimations
uncertainty adjustments
validation details Proof reading validation: Passed, Other validation: none, Validator: Mischa Zschokke, Company: Carbotech, Country: CH

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 kg. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 1.761 1.1 4.081 1.94
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 2.243 0.9592 7 2.79
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 454.8 276.9 1010 1.93
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.1888 0.1186 0.4349 1.96
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 457.2 277.7 1016 1.93
EF-particulate Matter Impact on human health disease incidence 1.426e-05 9.228e-06 3.584e-05 1.99
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 3742 2572 1.244e+04 2.21
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 90.26 55.03 214.6 1.98
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 3832 2634 1.264e+04 2.2
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 0.7315 0.4313 2.002 2.18
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 3.115 1.413 24.45 4.12
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 6.551 3.797 15.58 2.04
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 6.001e-07 4.185e-07 2.590e-06 2.58
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 1.231e-07 7.252e-08 2.840e-07 2.01
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 7.232e-07 5.080e-07 2.874e-06 2.43
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 4.093e-05 2.377e-05 1.888e-04 2.9
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 4.063e-07 2.625e-07 9.556e-07 1.91
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 4.133e-05 2.412e-05 1.895e-04 2.88
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 80.95 20.4 596.5 5.59
Land use Soil quality index pt (soil quality index) 4164 2212 1.136e+04 —
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 5.862e-05 3.219e-05 1.357e-04 2.07
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 1.857 1.176 4.414 1.96
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 5828 3562 1.377e+04 1.97
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 0.4978 0.2848 1.041 1.96
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 82.41 -1.172e+05 6.444e+04 —

Climate change 457.2 kg CO2 eq per kg. Main contributors: Integrated circuit, IC, logic type, at plant 72 %; Integrated circuit, IC, memory type, at plant 23 %; Transistor, unspecified, at plant 3 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Integrated circuit, IC, logic type, at plant 72 %; Integrated circuit, IC, memory type, at plant 23 %; Transistor, unspecified, at plant 3 %. Most sensitive exchanges (Section 6.3): Integrated circuit, IC, logic type, at plant [GLO] (-40.8 / +93.5 %); Integrated circuit, IC, memory type, at plant [GLO] (-13.2 / +30.3 %); Transistor, unspecified, at plant [GLO] (-1.8 / +4.1 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 1.761 2.056 0.857
Climate change-Biogenic 2.243 2.243 1.000
Climate change-Fossil 454.8 454.8 1.000
Climate change-Land use and land use change 0.1888 0.1888 1.000
Climate change 457.2 457.2 1.000
EF-particulate Matter 1.426e-05 1.426e-05 1.000
Ecotoxicity, freshwater_inorganics 3742 3869 0.967
Ecotoxicity, freshwater_organics 90.26 68.43 1.319
Ecotoxicity, freshwater 3832 3769 1.017
Eutrophication marine 0.7315 0.7315 1.000
Eutrophication, freshwater 3.115 3.115 1.000
Eutrophication, terrestrial 6.551 6.9 0.949
Human toxicity, cancer_inorganics 6.001e-07 5.956e-07 1.008
Human toxicity, cancer_organics 1.231e-07 1.231e-07 1.000
Human toxicity, cancer 7.232e-07 7.188e-07 1.006
Human toxicity, non-cancer_inorganics 4.093e-05 4.043e-05 1.012
Human toxicity, non-cancer_organics 4.063e-07 4.060e-07 1.001
Human toxicity, non-cancer 4.133e-05 4.084e-05 1.012
Ionising radiation, human health 80.95 80.95 1.000
Land use 4164 3719 1.120
Ozone depletion 5.862e-05 5.862e-05 1.000
Photochemical ozone formation - human health 1.857 1.857 1.000
Resource use, fossils 5828 5831 0.999
Resource use, minerals and metals 0.4978 0.4977 1.000
Water use 82.41 99.36 0.829
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 457.1 kg CO2 eq; Ecological Scarcity
2021 total 2.846e+06 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Integrated circuit, IC, logic type, at plant [GLO] 0.55 kg ×0.437 / ×2.29 lognormal, GSD² 2.33 -40.8 / +93.5 93.5 (Climate change-Fossil)
Integrated circuit, IC, memory type, at plant [GLO] 0.309 kg ×0.437 / ×2.29 lognormal, GSD² 2.33 -13.2 / +30.3 43.8 (Ozone depletion)
Transistor, unspecified, at plant [GLO] 0.117 kg ×0.437 / ×2.29 lognormal, GSD² 2.33 -1.8 / +4.1 8.5 (Human toxicity, non-cancer_organics)
Diode, unspecified, at plant [GLO] 0.0196 kg ×0.437 / ×2.29 lognormal, GSD² 2.33 -0.5 / +1.0 2.0 (Ionising radiation, human health)
Light emitting diode, LED, at plant [GLO] 0.00375 kg ×0.437 / ×2.29 lognormal, GSD² 2.33 -0.1 / +0.2 0.4 (Ionising radiation, human health)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 457.2 kg CO2 eq per kg (95 % interval 277.7–1016). Dominant contributors: Integrated circuit, IC, logic type, at plant 72 %; Integrated circuit, IC, memory type, at plant 23 %; Transistor, unspecified, at plant 3 %. Most sensitive: Integrated circuit, IC, logic type, at plant [GLO] (-40.8 / +93.5 %); Integrated circuit, IC, memory type, at plant [GLO] (-13.2 / +30.3 %); Transistor, unspecified, at plant [GLO] (-1.8 / +4.1 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 kg
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 2.3e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 20/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 5/5 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 457.2 in [277.7, 1016]
time period declared PASS 2023-01/2029-12
geography is a known location code PASS GLO
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Raka Adrianto L. (2024) 2024 - LCI ICT sector - Raka Adrianto. Empa — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.

datasets/bafu/da6d0b4c-54ad-3388-8d07-38caeda40d00.txt · Last modified: by 127.0.0.1

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki