Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset EKG I, electrical system, residental building, construction [CH], per 1 m2. EF v3.1 climate change 8.816 kg CO2 eq (Monte Carlo 95 % interval 8.167–13.22). Main contributors: Polyethylene, HDPE, granulate, at plant 21 %; Printed wiring board mounting plant 14 %; Copper, at regional storage 11 %; Connector, computer, peripherical type, at plant 10 %; Polyvinylchloride, at regional storage 9 %; Steel, low-alloyed, at plant 5 %. Status: final control: 0 failed, 1 warning(s) (Section 7).
| Item | Value |
|---|---|
| Dataset name | EKG I, electrical system, residental building, construction |
| Dataset UUID / graph id | e297949c-b756-3727-a256-cfcca08aae59 / activity:ekg_i_electrical_system_residental_building_construction__ch |
| Reference product, unit | EKG I, electrical system, residental building, construction, 1 m2 |
| Location | CH — Data for Zurich, Switzerland |
| Time period | 2013-01/2013-12 |
| Category | construction processes / buildings |
| Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 |
| Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) |
| Background database | BAFU 2026 v1 (graph bafuquery-db) |
| LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) |
| Status | final control: 0 failed, 1 warning(s) (Section 7) |
| Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 |
Introduction
Elektroanlagen, tiefer Installationsgrad; UUID: e297949c-b756-3727-a256-cfcca08aae59
This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.
Goal and scope
Function, functional unit and reference flow
Reference flow: 1 m2 of EKG I, electrical system, residental building, construction (CH). All results are given per unit of the reference flow.
System boundary
This data set includes the material use for the manufacturing of the electronic installations in the residental building according to Klingler and Kasser, 2011. The source states that 95 % of the mass volume is accounted for, which covers about 100 individual components. 5 newly constructed multi-familiy residental buildings were taken into account. The connection to the public electricity grid was not taken into account. Only the basic equipment was accounted for (light in staircase and basement). The neon tubes and lamp fitting, as well as the control gear (EVG and VVG) were modelled with an energy saving light bulb. The electrical system has a life-span of 30 years. Transport is included.
Technology
Average technology
Link to the background database
Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).
LCIA method
EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.
Life cycle inventory
Inventory table
Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).
| Exchange | Type | Location / compartment | Amount | Unit | Uncertainty | Pedigree | GWP share (%) | Notes | |
|---|---|---|---|---|---|---|---|---|---|
| Polyethylene, HDPE, granulate, at plant | technosphere | RER | 0.83232 | kg | none declared: tdc-doc default ±50 % | — | 21.4 | ████ | |
| Printed wiring board mounting plant | technosphere | GLO | 2.0279e-07 | p | none declared: tdc-doc default ±50 % | — | 14.2 | ███ | |
| Copper, at regional storage | technosphere | RER | 0.59138 | kg | none declared: tdc-doc default ±50 % | — | 10.8 | ██ | |
| Connector, computer, peripherical type, at plant | technosphere | GLO | 0.13988 | kg | none declared: tdc-doc default ±50 % | — | 10.4 | ██ | |
| Polyvinylchloride, at regional storage | technosphere | RER | 0.32343 | kg | none declared: tdc-doc default ±50 % | — | 8.6 | ██ | |
| Steel, low-alloyed, at plant | technosphere | RER | 0.21794 | kg | none declared: tdc-doc default ±50 % | — | 5.3 | █ | |
| Electronics for control units | technosphere | RER | 0.024819 | kg | none declared: tdc-doc default ±50 % | — | 5.2 | █ | |
| Energy-saving bulb, 11W, incl. integrated adapter, at plant | technosphere | RER | 0.21828 | p | none declared: tdc-doc default ±50 % | — | 4.4 | █ | |
| Electricity, medium voltage, production ENTSO-E, at grid | technosphere | ENTSO-E | 1.3775 | kWh | none declared: tdc-doc default ±50 % | — | 4.3 | █ | |
| Extrusion, plastic pipes | technosphere | RER | 1.209 | kg | none declared: tdc-doc default ±50 % | — | 3.5 | █ | |
| Wire drawing, copper | technosphere | RER | 0.58399 | kg | none declared: tdc-doc default ±50 % | — | 2.5 | · | |
| Switch, toggle type, at plant | technosphere | GLO | 0.01406 | kg | none declared: tdc-doc default ±50 % | — | 1.9 | · | |
| Acrylonitrile-butadiene-styrene copolymer, ABS, at plant | technosphere | RER | 0.029172 | kg | none declared: tdc-doc default ±50 % | — | 1.5 | · | |
| Aluminium, production mix, at plant | technosphere | RER | 0.02445 | kg | none declared: tdc-doc default ±50 % | — | 1.3 | · | |
| Zinc coating, pieces | technosphere | RER | 0.013033 | m2 | none declared: tdc-doc default ±50 % | — | 0.9 | · | |
| Heat, heavy fuel oil, at industrial furnace 1MW | technosphere | CH | 0.61252 | MJ | none declared: tdc-doc default ±50 % | — | 0.7 | · | |
| Disposal, plastics, mixture, 15.3% water, to municipal incineration | technosphere | CH | 0.024338 | kg | none declared: tdc-doc default ±50 % | — | 0.7 | · | |
| Transport, freight, lorry, fleet average | technosphere | RER | 0.20412 | tkm | none declared: tdc-doc default ±50 % | — | 0.4 | · | |
| Extrusion, plastic pipes | technosphere | RER | 0.13282 | kg | none declared: tdc-doc default ±50 % | — | 0.4 | · | |
| Wire drawing, steel | technosphere | RER | 0.085241 | kg | none declared: tdc-doc default ±50 % | — | 0.4 | · | |
| Polystyrene, high impact, HIPS, at plant | technosphere | RER | 0.0091105 | kg | none declared: tdc-doc default ±50 % | — | 0.4 | · | |
| Glass fibre reinforced plastic, polyamide, injection moulding, at plant | technosphere | RER | 0.0030274 | kg | none declared: tdc-doc default ±50 % | — | 0.3 | · | |
| Polypropylene, granulate, at plant | technosphere | RER | 0.011542 | kg | none declared: tdc-doc default ±50 % | — | 0.3 | · | |
| Section bar extrusion, aluminium | technosphere | RER | 0.02445 | kg | none declared: tdc-doc default ±50 % | — | 0.2 | · | |
| Transport, freight, rail, electricity with shunting | technosphere | CH | 0.40865 | tkm | none declared: tdc-doc default ±50 % | — | 0.1 | · | |
| Chromium steel 18/8, at plant | technosphere | RER | 6.9375e-04 | kg | none declared: tdc-doc default ±50 % | — | 0.0 | · | |
| Tap water, at user | technosphere | CH | 19.67 | kg | none declared: tdc-doc default ±50 % | — | 0.0 | · | |
| Sheet rolling, copper | technosphere | RER | 0.0073886 | kg | none declared: tdc-doc default ±50 % | — | 0.0 | · | |
| Sheet rolling, aluminium | technosphere | RER | 4.3728e-04 | kg | none declared: tdc-doc default ±50 % | — | 0.0 | · | |
| Propane, butane, at refinery | technosphere | RER | 1.8068e-04 | kg | none declared: tdc-doc default ±50 % | — | 0.0 | · | |
| Sawnwood, production mix, softwood, dried (u=10%), planed, at sawmill | technosphere | RER | 2.6093e-06 | m3 | none declared: tdc-doc default ±50 % | — | 0.0 | · |
Data quality
0 of 31 direct exchanges carry a declared pedigree, 0 carry a distribution.
| Field | As declared by the publisher |
|---|---|
| Data generator / entry / validation | data generator: Franziska Wyss (TREEZE); data entry: Franziska Wyss (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE) |
| extrapolations | none |
| sampling procedure | unknown |
| production volume | na |
| uncertainty adjustments | none |
| validation details | Proof reading validation: 12.11.2013; Other validation: \Server\E\ESU-Docs\Projekte laufend\494 IEA Annex 57\EcoSpold\Haustechnik[494_ecospold_Sanitär_Elektro_v0.4.xlsx]X-Process; |
| time period comment | undefined |
Data gaps, proxies and assumptions
| Item | Class | Value used | Reason | Effect |
|---|---|---|---|---|
| 31 exchange(s) without declared uncertainty | uncertainty | fixed in the Monte Carlo | the publisher declares no distribution | ±50 % in the sensitivity check (Section 6.3) |
Life cycle impact assessment (EF v3.1)
Per 1 m2. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.
| Impact category | Indicator | Unit | Result | 2.5 % | 97.5 % | GSD² |
|---|---|---|---|---|---|---|
| Acidification | Accumulated Exceedance (AE) | mol H+ eq | 0.1407 | 0.1239 | 0.1956 | 1.27 |
| Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 0.02955 | 0.0205 | 0.068 | 1.86 |
| Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 8.783 | 8.128 | 13.17 | 1.28 |
| Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 0.003113 | 0.002773 | 0.00527 | 1.4 |
| Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 8.816 | 8.167 | 13.22 | 1.28 |
| EF-particulate Matter | Impact on human health | disease incidence | 5.666e-07 | 5.391e-07 | 9.919e-07 | 1.36 |
| Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 69.8 | 65.68 | 162.4 | 1.61 |
| Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 1.175 | 1.144 | 2.236 | 1.51 |
| Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 70.98 | 67.22 | 163.7 | 1.6 |
| Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | 0.01299 | 0.01134 | 0.02231 | 1.46 |
| Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | 0.04364 | 0.02738 | 0.269 | 3.43 |
| Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | 0.1512 | 0.125 | 0.2465 | 1.42 |
| Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | 1.619e-08 | 1.451e-08 | 4.507e-08 | 1.81 |
| Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | 3.012e-09 | 2.699e-09 | 7.308e-09 | 1.67 |
| Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | 1.920e-08 | 1.834e-08 | 5.089e-08 | 1.7 |
| Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | 1.554e-06 | 1.315e-06 | 4.351e-06 | 1.84 |
| Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | 1.195e-07 | 7.762e-08 | 2.166e-07 | 1.69 |
| Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | 1.674e-06 | 1.431e-06 | 4.493e-06 | 1.78 |
| Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | 2.17 | 0.8775 | 13.36 | 4.09 |
| Land use | Soil quality index | pt (soil quality index) | 116.9 | 89.09 | 241.5 | 1.69 |
| Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | 5.356e-07 | 4.087e-07 | 1.059e-06 | 1.62 |
| Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | 0.04596 | 0.04278 | 0.06652 | 1.26 |
| Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | 163.5 | 140.3 | 268 | 1.39 |
| Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | 0.001439 | 0.001233 | 0.00196 | 1.28 |
| Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | 1.121 | -3551 | 1817 | — |
Climate change 8.816 kg CO2 eq per m2. Main contributors: Polyethylene, HDPE, granulate, at plant 21 %; Printed wiring board mounting plant 14 %; Copper, at regional storage 11 %; Connector, computer, peripherical type, at plant 10 %; Polyvinylchloride, at regional storage 9 %; Steel, low-alloyed, at plant 5 %.
Interpretation
Significant issues
Direct exchanges dominating climate change: Polyethylene, HDPE, granulate, at plant 21 %; Printed wiring board mounting plant 14 %; Copper, at regional storage 11 %; Connector, computer, peripherical type, at plant 10 %; Polyvinylchloride, at regional storage 9 %; Steel, low-alloyed, at plant 5 %. Most sensitive exchanges (Section 6.3): Polyethylene, HDPE, granulate, at plant [RER] (-10.7 / +10.7 %); Printed wiring board mounting plant [GLO] (-7.1 / +7.1 %); Copper, at regional storage [RER] (-5.4 / +5.4 %).
Independent recalculation
Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):
| Category | Graph | Published | Graph / published |
|---|---|---|---|
| Acidification | 0.1407 | 0.143 | 0.984 |
| Climate change-Biogenic | 0.02955 | 0.02955 | 1.000 |
| Climate change-Fossil | 8.783 | 8.783 | 1.000 |
| Climate change-Land use and land use change | 0.003113 | 0.003113 | 1.000 |
| Climate change | 8.816 | 8.816 | 1.000 |
| EF-particulate Matter | 5.666e-07 | 5.666e-07 | 1.000 |
| Ecotoxicity, freshwater_inorganics | 69.8 | 71.88 | 0.971 |
| Ecotoxicity, freshwater_organics | 1.175 | 1.158 | 1.015 |
| Ecotoxicity, freshwater | 70.98 | 72.83 | 0.975 |
| Eutrophication marine | 0.01299 | 0.01299 | 1.000 |
| Eutrophication, freshwater | 0.04364 | 0.04364 | 1.000 |
| Eutrophication, terrestrial | 0.1512 | 0.1547 | 0.977 |
| Human toxicity, cancer_inorganics | 1.619e-08 | 1.613e-08 | 1.004 |
| Human toxicity, cancer_organics | 3.012e-09 | 3.012e-09 | 1.000 |
| Human toxicity, cancer | 1.920e-08 | 1.914e-08 | 1.003 |
| Human toxicity, non-cancer_inorganics | 1.554e-06 | 1.551e-06 | 1.002 |
| Human toxicity, non-cancer_organics | 1.195e-07 | 1.195e-07 | 1.000 |
| Human toxicity, non-cancer | 1.674e-06 | 1.670e-06 | 1.002 |
| Ionising radiation, human health | 2.17 | 2.17 | 1.000 |
| Land use | 116.9 | 83 | 1.408 |
| Ozone depletion | 5.356e-07 | 5.356e-07 | 1.000 |
| Photochemical ozone formation - human health | 0.04596 | 0.04596 | 1.000 |
| Resource use, fossils | 163.5 | 163.5 | 1.000 |
| Resource use, minerals and metals | 0.001439 | 0.001426 | 1.009 |
| Water use | 1.121 | 1.406 | 0.797 |
| Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | |||
| Also published by BAFU for this dataset: IPCC 2021 GWP100 8.815 kg CO2 eq; Ecological Scarcity | |||
| 2021 total 3.424e+04 UBP. |
Sensitivity check
One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.
| Exchange | Base | Low / high | Range | Δ GWP100 (%) | Δ other categories (max %) |
|---|---|---|---|---|---|
| Polyethylene, HDPE, granulate, at plant [RER] | 0.8323 kg | ×0.5 / ×1.5 | none declared: tdc-doc default ±50 % | -10.7 / +10.7 | 18.4 (Resource use, fossils) |
| Printed wiring board mounting plant [GLO] | 2.028e-07 p | ×0.5 / ×1.5 | none declared: tdc-doc default ±50 % | -7.1 / +7.1 | 26.1 (Land use) |
| Copper, at regional storage [RER] | 0.5914 kg | ×0.5 / ×1.5 | none declared: tdc-doc default ±50 % | -5.4 / +5.4 | 39.0 (Human toxicity, non-cancer_organics) |
| Connector, computer, peripherical type, at plant [GLO] | 0.1399 kg | ×0.5 / ×1.5 | none declared: tdc-doc default ±50 % | -5.2 / +5.2 | 9.6 (Climate change-Land use and land use change) |
| Polyvinylchloride, at regional storage [RER] | 0.3234 kg | ×0.5 / ×1.5 | none declared: tdc-doc default ±50 % | -4.3 / +4.3 | 27.7 (Ozone depletion) |
| Steel, low-alloyed, at plant [RER] | 0.2179 kg | ×0.5 / ×1.5 | none declared: tdc-doc default ±50 % | -2.6 / +2.6 | 3.2 (Human toxicity, cancer_organics) |
| Electronics for control units [RER] | 0.02482 kg | ×0.5 / ×1.5 | none declared: tdc-doc default ±50 % | -2.6 / +2.6 | 9.2 (Resource use, minerals and metals) |
| Energy-saving bulb, 11W, incl. integrated adapter, at plant [RER] | 0.2183 p | ×0.5 / ×1.5 | none declared: tdc-doc default ±50 % | -2.2 / +2.2 | 3.3 (Water use) |
| Electricity, medium voltage, production ENTSO-E, at grid [ENTSO-E] | 1.377 kWh | ×0.5 / ×1.5 | none declared: tdc-doc default ±50 % | -2.1 / +2.1 | 11.5 (Ionising radiation, human health) |
| Extrusion, plastic pipes [RER] | 1.209 kg | ×0.5 / ×1.5 | none declared: tdc-doc default ±50 % | -1.7 / +1.7 | 5.3 (Ionising radiation, human health) |
| Wire drawing, copper [RER] | 0.584 kg | ×0.5 / ×1.5 | none declared: tdc-doc default ±50 % | -1.2 / +1.2 | 2.8 (Climate change-Land use and land use change) |
| Switch, toggle type, at plant [GLO] | 0.01406 kg | ×0.5 / ×1.5 | none declared: tdc-doc default ±50 % | -1.0 / +1.0 | 8.3 (Resource use, minerals and metals) |
| Acrylonitrile-butadiene-styrene copolymer, ABS, at plant [RER] | 0.02917 kg | ×0.5 / ×1.5 | none declared: tdc-doc default ±50 % | -0.7 / +0.7 | 0.8 (Resource use, fossils) |
| Aluminium, production mix, at plant [RER] | 0.02445 kg | ×0.5 / ×1.5 | none declared: tdc-doc default ±50 % | -0.7 / +0.7 | 2.6 (Climate change-Land use and land use change) |
| Zinc coating, pieces [RER] | 0.01303 m2 | ×0.5 / ×1.5 | none declared: tdc-doc default ±50 % | -0.4 / +0.4 | 0.8 (Climate change-Land use and land use change) |
Uncertainty analysis
Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.
Comparison with other data
No other location of this dataset in the graph.
Conclusions and limitations
GWP100 8.816 kg CO2 eq per m2 (95 % interval 8.167–13.22). Dominant contributors: Polyethylene, HDPE, granulate, at plant 21 %; Printed wiring board mounting plant 14 %; Copper, at regional storage 11 %; Connector, computer, peripherical type, at plant 10 %; Polyvinylchloride, at regional storage 9 %; Steel, low-alloyed, at plant 5 %. Most sensitive: Polyethylene, HDPE, granulate, at plant [RER] (-10.7 / +10.7 %); Printed wiring board mounting plant [GLO] (-7.1 / +7.1 %); Copper, at regional storage [RER] (-5.4 / +5.4 %). final control: 0 failed, 1 warning(s) (Section 7). The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.
Final control
| Item | Status | Detail |
|---|---|---|
| reference flow | PASS | production amount 1.0 m2 |
| closure: sum of direct contributions = dataset score (all 25 categories) | PASS | largest relative gap 7.6e-16 |
| independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | PASS | graph / published = 1; categories within ±5 %: 23/25 |
| every technosphere input of the EcoSpold delivery is in the graph | PASS | all present (bafu_links_check.py) |
| uncertainty declared on the direct exchanges | WARN | 0/31 exchanges carry a distribution (0 %); the others enter the Monte Carlo as fixed values |
| Monte Carlo 95 % interval contains the deterministic score | PASS | 8.816 in [8.167, 13.22] |
| time period declared | PASS | 2013-01/2013-12 |
| geography is a known location code | PASS | CH |
| sources cited | PASS | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them |
References
- Klingler, Kasser (2011) Graue Energie von Sanitär- und Elektroanlagen. Project report. Page: 100. BfE. BfE. Type: Separate publication Source: Report First author: Klingler Other authors: Kasser Year: 2011 Title of anthology: Project report Place of publication: BfE Publisher: BfE — published source; as declared by BAFU (not found in OpenAlex/Crossref)
- Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
- International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
- Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
- European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
- Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236
Annex — licence and terms of use
BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.