OpenData Wiki

Dataset documentation and review before publication

User Tools

Site Tools


datasets:bafu:e297949c-b756-3727-a256-cfcca08aae59

EKG I, electrical system, residental building, construction — CH

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset EKG I, electrical system, residental building, construction [CH], per 1 m2. EF v3.1 climate change 8.816 kg CO2 eq (Monte Carlo 95 % interval 8.167–13.22). Main contributors: Polyethylene, HDPE, granulate, at plant 21 %; Printed wiring board mounting plant 14 %; Copper, at regional storage 11 %; Connector, computer, peripherical type, at plant 10 %; Polyvinylchloride, at regional storage 9 %; Steel, low-alloyed, at plant 5 %. Status: final control: 0 failed, 1 warning(s) (Section 7).
Item Value
Dataset name EKG I, electrical system, residental building, construction
Dataset UUID / graph id e297949c-b756-3727-a256-cfcca08aae59 / activity:ekg_i_electrical_system_residental_building_construction__ch
Reference product, unit EKG I, electrical system, residental building, construction, 1 m2
Location CH — Data for Zurich, Switzerland
Time period 2013-01/2013-12
Category construction processes / buildings
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control: 0 failed, 1 warning(s) (Section 7)
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

Elektroanlagen, tiefer Installationsgrad; UUID: e297949c-b756-3727-a256-cfcca08aae59

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 m2 of EKG I, electrical system, residental building, construction (CH). All results are given per unit of the reference flow.

System boundary

This data set includes the material use for the manufacturing of the electronic installations in the residental building according to Klingler and Kasser, 2011. The source states that 95 % of the mass volume is accounted for, which covers about 100 individual components. 5 newly constructed multi-familiy residental buildings were taken into account. The connection to the public electricity grid was not taken into account. Only the basic equipment was accounted for (light in staircase and basement). The neon tubes and lamp fitting, as well as the control gear (EVG and VVG) were modelled with an energy saving light bulb. The electrical system has a life-span of 30 years. Transport is included.

Technology

Average technology

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Polyethylene, HDPE, granulate, at plant technosphere RER 0.83232 kg none declared: tdc-doc default ±50 % — 21.4 ████
Printed wiring board mounting plant technosphere GLO 2.0279e-07 p none declared: tdc-doc default ±50 % — 14.2 ███
Copper, at regional storage technosphere RER 0.59138 kg none declared: tdc-doc default ±50 % — 10.8 ██
Connector, computer, peripherical type, at plant technosphere GLO 0.13988 kg none declared: tdc-doc default ±50 % — 10.4 ██
Polyvinylchloride, at regional storage technosphere RER 0.32343 kg none declared: tdc-doc default ±50 % — 8.6 ██
Steel, low-alloyed, at plant technosphere RER 0.21794 kg none declared: tdc-doc default ±50 % — 5.3 █
Electronics for control units technosphere RER 0.024819 kg none declared: tdc-doc default ±50 % — 5.2 █
Energy-saving bulb, 11W, incl. integrated adapter, at plant technosphere RER 0.21828 p none declared: tdc-doc default ±50 % — 4.4 █
Electricity, medium voltage, production ENTSO-E, at grid technosphere ENTSO-E 1.3775 kWh none declared: tdc-doc default ±50 % — 4.3 █
Extrusion, plastic pipes technosphere RER 1.209 kg none declared: tdc-doc default ±50 % — 3.5 █
Wire drawing, copper technosphere RER 0.58399 kg none declared: tdc-doc default ±50 % — 2.5 ·
Switch, toggle type, at plant technosphere GLO 0.01406 kg none declared: tdc-doc default ±50 % — 1.9 ·
Acrylonitrile-butadiene-styrene copolymer, ABS, at plant technosphere RER 0.029172 kg none declared: tdc-doc default ±50 % — 1.5 ·
Aluminium, production mix, at plant technosphere RER 0.02445 kg none declared: tdc-doc default ±50 % — 1.3 ·
Zinc coating, pieces technosphere RER 0.013033 m2 none declared: tdc-doc default ±50 % — 0.9 ·
Heat, heavy fuel oil, at industrial furnace 1MW technosphere CH 0.61252 MJ none declared: tdc-doc default ±50 % — 0.7 ·
Disposal, plastics, mixture, 15.3% water, to municipal incineration technosphere CH 0.024338 kg none declared: tdc-doc default ±50 % — 0.7 ·
Transport, freight, lorry, fleet average technosphere RER 0.20412 tkm none declared: tdc-doc default ±50 % — 0.4 ·
Extrusion, plastic pipes technosphere RER 0.13282 kg none declared: tdc-doc default ±50 % — 0.4 ·
Wire drawing, steel technosphere RER 0.085241 kg none declared: tdc-doc default ±50 % — 0.4 ·
Polystyrene, high impact, HIPS, at plant technosphere RER 0.0091105 kg none declared: tdc-doc default ±50 % — 0.4 ·
Glass fibre reinforced plastic, polyamide, injection moulding, at plant technosphere RER 0.0030274 kg none declared: tdc-doc default ±50 % — 0.3 ·
Polypropylene, granulate, at plant technosphere RER 0.011542 kg none declared: tdc-doc default ±50 % — 0.3 ·
Section bar extrusion, aluminium technosphere RER 0.02445 kg none declared: tdc-doc default ±50 % — 0.2 ·
Transport, freight, rail, electricity with shunting technosphere CH 0.40865 tkm none declared: tdc-doc default ±50 % — 0.1 ·
Chromium steel 18/8, at plant technosphere RER 6.9375e-04 kg none declared: tdc-doc default ±50 % — 0.0 ·
Tap water, at user technosphere CH 19.67 kg none declared: tdc-doc default ±50 % — 0.0 ·
Sheet rolling, copper technosphere RER 0.0073886 kg none declared: tdc-doc default ±50 % — 0.0 ·
Sheet rolling, aluminium technosphere RER 4.3728e-04 kg none declared: tdc-doc default ±50 % — 0.0 ·
Propane, butane, at refinery technosphere RER 1.8068e-04 kg none declared: tdc-doc default ±50 % — 0.0 ·
Sawnwood, production mix, softwood, dried (u=10%), planed, at sawmill technosphere RER 2.6093e-06 m3 none declared: tdc-doc default ±50 % — 0.0 ·

Data quality

0 of 31 direct exchanges carry a declared pedigree, 0 carry a distribution.

Field As declared by the publisher
Data generator / entry / validation data generator: Franziska Wyss (TREEZE); data entry: Franziska Wyss (TREEZE); validation (proof reading): Rolf Frischknecht (TREEZE)
extrapolations none
sampling procedure unknown
production volume na
uncertainty adjustments none
validation details Proof reading validation: 12.11.2013; Other validation: \Server\E\ESU-Docs\Projekte laufend\494 IEA Annex 57\EcoSpold\Haustechnik[494_ecospold_Sanitär_Elektro_v0.4.xlsx]X-Process;
time period comment undefined

Data gaps, proxies and assumptions

Item Class Value used Reason Effect
31 exchange(s) without declared uncertainty uncertainty fixed in the Monte Carlo the publisher declares no distribution ±50 % in the sensitivity check (Section 6.3)

Life cycle impact assessment (EF v3.1)

Per 1 m2. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 0.1407 0.1239 0.1956 1.27
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.02955 0.0205 0.068 1.86
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 8.783 8.128 13.17 1.28
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.003113 0.002773 0.00527 1.4
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 8.816 8.167 13.22 1.28
EF-particulate Matter Impact on human health disease incidence 5.666e-07 5.391e-07 9.919e-07 1.36
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 69.8 65.68 162.4 1.61
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 1.175 1.144 2.236 1.51
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 70.98 67.22 163.7 1.6
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 0.01299 0.01134 0.02231 1.46
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 0.04364 0.02738 0.269 3.43
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 0.1512 0.125 0.2465 1.42
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.619e-08 1.451e-08 4.507e-08 1.81
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 3.012e-09 2.699e-09 7.308e-09 1.67
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 1.920e-08 1.834e-08 5.089e-08 1.7
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.554e-06 1.315e-06 4.351e-06 1.84
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 1.195e-07 7.762e-08 2.166e-07 1.69
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 1.674e-06 1.431e-06 4.493e-06 1.78
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 2.17 0.8775 13.36 4.09
Land use Soil quality index pt (soil quality index) 116.9 89.09 241.5 1.69
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 5.356e-07 4.087e-07 1.059e-06 1.62
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 0.04596 0.04278 0.06652 1.26
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 163.5 140.3 268 1.39
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 0.001439 0.001233 0.00196 1.28
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 1.121 -3551 1817 —

Climate change 8.816 kg CO2 eq per m2. Main contributors: Polyethylene, HDPE, granulate, at plant 21 %; Printed wiring board mounting plant 14 %; Copper, at regional storage 11 %; Connector, computer, peripherical type, at plant 10 %; Polyvinylchloride, at regional storage 9 %; Steel, low-alloyed, at plant 5 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Polyethylene, HDPE, granulate, at plant 21 %; Printed wiring board mounting plant 14 %; Copper, at regional storage 11 %; Connector, computer, peripherical type, at plant 10 %; Polyvinylchloride, at regional storage 9 %; Steel, low-alloyed, at plant 5 %. Most sensitive exchanges (Section 6.3): Polyethylene, HDPE, granulate, at plant [RER] (-10.7 / +10.7 %); Printed wiring board mounting plant [GLO] (-7.1 / +7.1 %); Copper, at regional storage [RER] (-5.4 / +5.4 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 0.1407 0.143 0.984
Climate change-Biogenic 0.02955 0.02955 1.000
Climate change-Fossil 8.783 8.783 1.000
Climate change-Land use and land use change 0.003113 0.003113 1.000
Climate change 8.816 8.816 1.000
EF-particulate Matter 5.666e-07 5.666e-07 1.000
Ecotoxicity, freshwater_inorganics 69.8 71.88 0.971
Ecotoxicity, freshwater_organics 1.175 1.158 1.015
Ecotoxicity, freshwater 70.98 72.83 0.975
Eutrophication marine 0.01299 0.01299 1.000
Eutrophication, freshwater 0.04364 0.04364 1.000
Eutrophication, terrestrial 0.1512 0.1547 0.977
Human toxicity, cancer_inorganics 1.619e-08 1.613e-08 1.004
Human toxicity, cancer_organics 3.012e-09 3.012e-09 1.000
Human toxicity, cancer 1.920e-08 1.914e-08 1.003
Human toxicity, non-cancer_inorganics 1.554e-06 1.551e-06 1.002
Human toxicity, non-cancer_organics 1.195e-07 1.195e-07 1.000
Human toxicity, non-cancer 1.674e-06 1.670e-06 1.002
Ionising radiation, human health 2.17 2.17 1.000
Land use 116.9 83 1.408
Ozone depletion 5.356e-07 5.356e-07 1.000
Photochemical ozone formation - human health 0.04596 0.04596 1.000
Resource use, fossils 163.5 163.5 1.000
Resource use, minerals and metals 0.001439 0.001426 1.009
Water use 1.121 1.406 0.797
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 8.815 kg CO2 eq; Ecological Scarcity
2021 total 3.424e+04 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Polyethylene, HDPE, granulate, at plant [RER] 0.8323 kg ×0.5 / ×1.5 none declared: tdc-doc default ±50 % -10.7 / +10.7 18.4 (Resource use, fossils)
Printed wiring board mounting plant [GLO] 2.028e-07 p ×0.5 / ×1.5 none declared: tdc-doc default ±50 % -7.1 / +7.1 26.1 (Land use)
Copper, at regional storage [RER] 0.5914 kg ×0.5 / ×1.5 none declared: tdc-doc default ±50 % -5.4 / +5.4 39.0 (Human toxicity, non-cancer_organics)
Connector, computer, peripherical type, at plant [GLO] 0.1399 kg ×0.5 / ×1.5 none declared: tdc-doc default ±50 % -5.2 / +5.2 9.6 (Climate change-Land use and land use change)
Polyvinylchloride, at regional storage [RER] 0.3234 kg ×0.5 / ×1.5 none declared: tdc-doc default ±50 % -4.3 / +4.3 27.7 (Ozone depletion)
Steel, low-alloyed, at plant [RER] 0.2179 kg ×0.5 / ×1.5 none declared: tdc-doc default ±50 % -2.6 / +2.6 3.2 (Human toxicity, cancer_organics)
Electronics for control units [RER] 0.02482 kg ×0.5 / ×1.5 none declared: tdc-doc default ±50 % -2.6 / +2.6 9.2 (Resource use, minerals and metals)
Energy-saving bulb, 11W, incl. integrated adapter, at plant [RER] 0.2183 p ×0.5 / ×1.5 none declared: tdc-doc default ±50 % -2.2 / +2.2 3.3 (Water use)
Electricity, medium voltage, production ENTSO-E, at grid [ENTSO-E] 1.377 kWh ×0.5 / ×1.5 none declared: tdc-doc default ±50 % -2.1 / +2.1 11.5 (Ionising radiation, human health)
Extrusion, plastic pipes [RER] 1.209 kg ×0.5 / ×1.5 none declared: tdc-doc default ±50 % -1.7 / +1.7 5.3 (Ionising radiation, human health)
Wire drawing, copper [RER] 0.584 kg ×0.5 / ×1.5 none declared: tdc-doc default ±50 % -1.2 / +1.2 2.8 (Climate change-Land use and land use change)
Switch, toggle type, at plant [GLO] 0.01406 kg ×0.5 / ×1.5 none declared: tdc-doc default ±50 % -1.0 / +1.0 8.3 (Resource use, minerals and metals)
Acrylonitrile-butadiene-styrene copolymer, ABS, at plant [RER] 0.02917 kg ×0.5 / ×1.5 none declared: tdc-doc default ±50 % -0.7 / +0.7 0.8 (Resource use, fossils)
Aluminium, production mix, at plant [RER] 0.02445 kg ×0.5 / ×1.5 none declared: tdc-doc default ±50 % -0.7 / +0.7 2.6 (Climate change-Land use and land use change)
Zinc coating, pieces [RER] 0.01303 m2 ×0.5 / ×1.5 none declared: tdc-doc default ±50 % -0.4 / +0.4 0.8 (Climate change-Land use and land use change)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 8.816 kg CO2 eq per m2 (95 % interval 8.167–13.22). Dominant contributors: Polyethylene, HDPE, granulate, at plant 21 %; Printed wiring board mounting plant 14 %; Copper, at regional storage 11 %; Connector, computer, peripherical type, at plant 10 %; Polyvinylchloride, at regional storage 9 %; Steel, low-alloyed, at plant 5 %. Most sensitive: Polyethylene, HDPE, granulate, at plant [RER] (-10.7 / +10.7 %); Printed wiring board mounting plant [GLO] (-7.1 / +7.1 %); Copper, at regional storage [RER] (-5.4 / +5.4 %). final control: 0 failed, 1 warning(s) (Section 7). The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 m2
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 7.6e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 23/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges WARN 0/31 exchanges carry a distribution (0 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 8.816 in [8.167, 13.22]
time period declared PASS 2013-01/2013-12
geography is a known location code PASS CH
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Klingler, Kasser (2011) Graue Energie von Sanitär- und Elektroanlagen. Project report. Page: 100. BfE. BfE. Type: Separate publication Source: Report First author: Klingler Other authors: Kasser Year: 2011 Title of anthology: Project report Place of publication: BfE Publisher: BfE — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.

datasets/bafu/e297949c-b756-3727-a256-cfcca08aae59.txt · Last modified: by 127.0.0.1