Table of Contents
Ventilation of dwellings, decentralized, 6 x 120 m3/h, steel ducts, without GHE — CH
Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData
Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Ventilation of dwellings, decentralized, 6 x 120 m3/h, steel ducts, without GHE [CH], per 1 m2a. EF v3.1 climate change 0.715 kg CO2 eq (Monte Carlo 95 % interval 0.6655–0.9373). Main contributors: Electricity, low voltage, at grid 49 %; Ventilation system, decentralized, 6 x 120 m3/h, steel ducts… 30 %; Ventilation equipment, decentralized, 180-250 m3/h, at plant 9 %; Silencer, steel, DN 125, at plant 5 %; Air filter, decentralized unit, 180-250 m3/h, at plant 2 %; Disposal, ventilation equipment, decentralized, 180-250 m3 1 %. Status: final control passed.
| Item | Value |
|---|---|
| Dataset name | Ventilation of dwellings, decentralized, 6 x 120 m3/h, steel ducts, without GHE |
| Dataset UUID / graph id | e4c3e0cd-7e76-31fb-b1bd-d81c9c311b38 / activity:ventilation_of_dwellings_decentralized_6_x_120_m3_h_steel_ducts_without_ghe__ch |
| Reference product, unit | Ventilation of dwellings, decentralized, 6 x 120 m3/h, steel ducts, without GHE, 1 m2a |
| Location | CH |
| Time period | 2003-01/2003-12 |
| Category | ventilation / unspecified |
| Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 |
| Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) |
| Background database | BAFU 2026 v1 (graph bafuquery-db) |
| LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) |
| Status | final control passed |
| Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 |
Introduction
Life time of system and ducts 50 years. Life time of ventilation unit 20 years. Life time of filters 1 year. Ventilation system for a multi family house. The house considered in the investigation includes 6 flats with 130 m2 floor area each and a ventilation rate of 120 m3/h. The influence of a smaller concrete demand due to embedment of ventilation tubes in the concrete of the floor (-8.05 kg concrete per m2 floor area) is not included.; UUID: e4c3e0cd-7e76-31fb-b1bd-d81c9c311b38
This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.
Goal and scope
Function, functional unit and reference flow
Reference flow: 1 m2a of Ventilation of dwellings, decentralized, 6 x 120 m3/h, steel ducts, without GHE (CH). All results are given per unit of the reference flow.
System boundary
Materials used for the construction and renewal of the ventilation system. Electricity for the operation of the system on 12 month per year included. Transport of the components to the construction site. Disposal of the components included. Influence of ventilation ducts on building construction not included.
Technology
Electricity demand of ventilator (0.4 Wh/m3) representative for DC- or EC-motors and a system design with low pressure drops. Electricity demand of control unit 10 W. Additional 0.3 kWh/(m2 a) electricity demand for defrosting of heat exchanger. Decentral ventilation system without ground heat exchanger. Air intake on the facade and direct to the 6 decentral ventilation units with a short galvanised steel tube (125 mm diameter). Distribution of fresh- and exhaust-air within the flat with galvanised steel ducts (100×50 mm). Exhaust air from the 6 decentral ventilation units with a short galvanised steel tube (400 mm diameter) direct to the exhaust on the facade.
Link to the background database
Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).
LCIA method
EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.
Life cycle inventory
Inventory table
Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).
| Exchange | Type | Location / compartment | Amount | Unit | Uncertainty | Pedigree | GWP share (%) | Notes | |
|---|---|---|---|---|---|---|---|---|---|
| Electricity, low voltage, at grid | technosphere | CH | 3.65 | kWh | lognormal, GSD² 1.14 | (2,3,1,1,1,4) | 49.5 | ██████████ | |
| Ventilation system, decentralized, 6 x 120 m3/h, steel ducts, without GHE | technosphere | CH | 2.5600e-05 | p | lognormal, GSD² 1.15 | — | 30.1 | ██████ | |
| Ventilation equipment, decentralized, 180-250 m3/h, at plant | technosphere | RER | 3.0800e-04 | p | lognormal, GSD² 1.15 | — | 9.1 | ██ | |
| Silencer, steel, DN 125, at plant | technosphere | CH | 0.00123 | p | lognormal, GSD² 1.15 | — | 4.9 | █ | |
| Air filter, decentralized unit, 180-250 m3/h, at plant | technosphere | RER | 0.0151 | p | lognormal, GSD² 1.15 | — | 2.1 | · | |
| Disposal, ventilation equipment, decentralized, 180-250 m3 | technosphere | CH | 3.0800e-04 | p | lognormal, GSD² 1.15 | — | 1.3 | · | |
| Air filter, in exhaust air valve, at plant | technosphere | RER | 0.0226 | p | lognormal, GSD² 1.15 | — | 0.9 | · | |
| Control and wiring, decentralized unit, at plant | technosphere | RER | 3.0800e-04 | p | lognormal, GSD² 1.15 | — | 0.7 | · | |
| Disposal, air filter, decentralized unit, 180-250 m3/h | technosphere | CH | 0.0151 | p | lognormal, GSD² 1.15 | — | 0.5 | · | |
| Disposal, air filter, in exhaust air valve | technosphere | CH | 0.0226 | p | lognormal, GSD² 1.15 | — | 0.3 | · | |
| Transport, freight, lorry, 3.5t gross weight, fleet average | technosphere | CH | 0.00143 | tkm | lognormal, GSD² 2.06 | — | 0.2 | · | |
| Transport, freight, lorry, fleet average | technosphere | RER | 0.00493 | tkm | lognormal, GSD² 2.03 | — | 0.1 | · | |
| Flexible duct, aluminum/PET, DN of 125, at plant | technosphere | RER | 0.00103 | m | lognormal, GSD² 1.15 | — | 0.1 | · | |
| Disposal, control and wiring, decentralized unit | technosphere | CH | 3.0800e-04 | p | lognormal, GSD² 1.15 | — | 0.1 | · | |
| Disposal, flexible duct, aluminum/PET, DN of 125 | technosphere | CH | 0.00103 | m | lognormal, GSD² 1.15 | — | 0.0 | · | |
| Disposal, silencer, steel, DN 125 | technosphere | CH | 0.00123 | p | lognormal, GSD² 1.15 | — | 0.0 | · | |
| Transport, freight, lorry, 16t-32t gross weight, fleet average | technosphere | CH | 2.0400e-04 | tkm | lognormal, GSD² 2.03 | — | 0.0 | · |
Data quality
1 of 17 direct exchanges carry a declared pedigree, 17 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.0 · completeness 3.0 · temporal 1.0 · geographical 1.0 · technological 1.0 · sample size 4.0.
| Field | As declared by the publisher |
|---|---|
| Data generator / entry / validation | data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Rolf Frischknecht (TREEZE) |
| extrapolations | none |
| sampling procedure | Questionnaire, technical information and assumptions. Data valid for example building used. |
| production volume | na |
| uncertainty adjustments | none |
| validation details | Proof reading validation: passed; Other validation: none; |
| time period comment | Amount of material investigated in 2003 |
Data gaps, proxies and assumptions
None recorded.
Life cycle impact assessment (EF v3.1)
Per 1 m2a. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.
| Impact category | Indicator | Unit | Result | 2.5 % | 97.5 % | GSD² |
|---|---|---|---|---|---|---|
| Acidification | Accumulated Exceedance (AE) | mol H+ eq | 0.007525 | 0.005003 | 0.01397 | 1.71 |
| Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 0.01041 | 0.007608 | 0.01675 | 1.51 |
| Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 0.7033 | 0.6528 | 0.9231 | 1.19 |
| Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 0.00131 | 9.573e-04 | 0.001967 | 1.46 |
| Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 0.715 | 0.6655 | 0.9373 | 1.19 |
| EF-particulate Matter | Impact on human health | disease incidence | 8.564e-08 | 6.675e-08 | 1.415e-07 | 1.48 |
| Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 2.849 | 2.752 | 5.554 | 1.45 |
| Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 0.05068 | 0.04913 | 0.108 | 1.51 |
| Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 2.9 | 2.806 | 5.638 | 1.44 |
| Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | 7.228e-04 | 6.651e-04 | 0.001037 | 1.27 |
| Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | 5.651e-04 | 3.599e-04 | 0.002398 | 2.61 |
| Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | 0.02863 | 0.01689 | 0.057 | 1.87 |
| Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | 2.748e-10 | 2.809e-10 | 7.232e-10 | 1.6 |
| Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | 3.099e-10 | 2.657e-10 | 5.397e-10 | 1.44 |
| Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | 5.847e-10 | 5.871e-10 | 1.135e-09 | 1.4 |
| Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | 2.331e-08 | 2.078e-08 | 6.632e-08 | 1.8 |
| Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | 1.090e-09 | 7.702e-10 | 2.302e-09 | 1.76 |
| Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | 2.440e-08 | 2.173e-08 | 6.817e-08 | 1.78 |
| Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | 2.718 | 0.9804 | 14.95 | 4.19 |
| Land use | Soil quality index | pt (soil quality index) | 7.647 | 5.932 | 12.8 | 1.5 |
| Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | 5.444e-08 | 4.587e-08 | 7.941e-08 | 1.32 |
| Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | 0.00181 | 0.001738 | 0.002842 | 1.3 |
| Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | 30.64 | 25.56 | 43.09 | 1.32 |
| Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | 1.685e-05 | -1.392e-05 | 7.466e-05 | — |
| Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | 0.2632 | -866 | 450.2 | — |
Climate change 0.715 kg CO2 eq per m2a. Main contributors: Electricity, low voltage, at grid 49 %; Ventilation system, decentralized, 6 x 120 m3/h, steel ducts… 30 %; Ventilation equipment, decentralized, 180-250 m3/h, at plant 9 %; Silencer, steel, DN 125, at plant 5 %; Air filter, decentralized unit, 180-250 m3/h, at plant 2 %; Disposal, ventilation equipment, decentralized, 180-250 m3 1 %.
Interpretation
Significant issues
Direct exchanges dominating climate change: Electricity, low voltage, at grid 49 %; Ventilation system, decentralized, 6 x 120 m3/h, steel ducts… 30 %; Ventilation equipment, decentralized, 180-250 m3/h, at plant 9 %; Silencer, steel, DN 125, at plant 5 %; Air filter, decentralized unit, 180-250 m3/h, at plant 2 %; Disposal, ventilation equipment, decentralized, 180-250 m3 1 %. Most sensitive exchanges (Section 6.3): Electricity, low voltage, at grid [CH] (-6.0 / +6.8 %); Ventilation system, decentralized, 6 x 120 m3/h, steel ducts, without GHE [CH] (-3.9 / +4.4 %); Ventilation equipment, decentralized, 180-250 m3/h, at plant [RER] (-1.2 / +1.3 %).
Independent recalculation
Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):
| Category | Graph | Published | Graph / published |
|---|---|---|---|
| Acidification | 0.007525 | 0.007772 | 0.968 |
| Climate change-Biogenic | 0.01041 | 0.01041 | 1.000 |
| Climate change-Fossil | 0.7033 | 0.7033 | 1.000 |
| Climate change-Land use and land use change | 0.00131 | 0.00131 | 1.000 |
| Climate change | 0.715 | 0.715 | 1.000 |
| EF-particulate Matter | 8.564e-08 | 8.564e-08 | 1.000 |
| Ecotoxicity, freshwater_inorganics | 2.849 | 2.936 | 0.970 |
| Ecotoxicity, freshwater_organics | 0.05068 | 0.04772 | 1.062 |
| Ecotoxicity, freshwater | 2.9 | 2.98 | 0.973 |
| Eutrophication marine | 7.228e-04 | 7.217e-04 | 1.002 |
| Eutrophication, freshwater | 5.651e-04 | 5.651e-04 | 1.000 |
| Eutrophication, terrestrial | 0.02863 | 0.02903 | 0.986 |
| Human toxicity, cancer_inorganics | 2.748e-10 | 2.691e-10 | 1.021 |
| Human toxicity, cancer_organics | 3.099e-10 | 3.099e-10 | 1.000 |
| Human toxicity, cancer | 5.847e-10 | 5.789e-10 | 1.010 |
| Human toxicity, non-cancer_inorganics | 2.331e-08 | 2.303e-08 | 1.012 |
| Human toxicity, non-cancer_organics | 1.090e-09 | 1.090e-09 | 1.000 |
| Human toxicity, non-cancer | 2.440e-08 | 2.412e-08 | 1.012 |
| Ionising radiation, human health | 2.718 | 2.718 | 1.000 |
| Land use | 7.647 | 6.077 | 1.258 |
| Ozone depletion | 5.444e-08 | 5.444e-08 | 1.000 |
| Photochemical ozone formation - human health | 0.00181 | 0.00181 | 1.000 |
| Resource use, fossils | 30.64 | 30.65 | 1.000 |
| Resource use, minerals and metals | 1.685e-05 | 1.657e-05 | 1.017 |
| Water use | 0.2632 | 0.2899 | 0.908 |
| Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | |||
| Also published by BAFU for this dataset: IPCC 2021 GWP100 0.7148 kg CO2 eq; Ecological Scarcity | |||
| 2021 total 2708 UBP. |
Sensitivity check
One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.
| Exchange | Base | Low / high | Range | Δ GWP100 (%) | Δ other categories (max %) |
|---|---|---|---|---|---|
| Electricity, low voltage, at grid [CH] | 3.65 kWh | ×0.879 / ×1.14 | lognormal, GSD² 1.14 | -6.0 / +6.8 | 13.2 (Ionising radiation, human health) |
| Ventilation system, decentralized, 6 x 120 m3/h, steel ducts, without GHE [CH] | 2.560e-05 p | ×0.872 / ×1.15 | lognormal, GSD² 1.15 | -3.9 / +4.4 | 10.8 (Eutrophication, terrestrial) |
| Ventilation equipment, decentralized, 180-250 m3/h, at plant [RER] | 3.080e-04 p | ×0.872 / ×1.15 | lognormal, GSD² 1.15 | -1.2 / +1.3 | 1.9 (Ecotoxicity, freshwater_organics) |
| Silencer, steel, DN 125, at plant [CH] | 0.00123 p | ×0.872 / ×1.15 | lognormal, GSD² 1.15 | -0.6 / +0.7 | 1.5 (Eutrophication, terrestrial) |
| Air filter, decentralized unit, 180-250 m3/h, at plant [RER] | 0.0151 p | ×0.872 / ×1.15 | lognormal, GSD² 1.15 | -0.3 / +0.3 | 1.1 (Land use) |
| Disposal, ventilation equipment, decentralized, 180-250 m3 [CH] | 3.080e-04 p | ×0.872 / ×1.15 | lognormal, GSD² 1.15 | -0.2 / +0.2 | 0.2 (Climate change-Fossil) |
| Transport, freight, lorry, 3.5t gross weight, fleet average [CH] | 0.00143 tkm | ×0.493 / ×2.03 | lognormal, GSD² 2.06 | -0.1 / +0.2 | 1.0 (Ecotoxicity, freshwater_organics) |
| Air filter, in exhaust air valve, at plant [RER] | 0.0226 p | ×0.872 / ×1.15 | lognormal, GSD² 1.15 | -0.1 / +0.1 | 0.3 (Ecotoxicity, freshwater_organics) |
| Transport, freight, lorry, fleet average [RER] | 0.00493 tkm | ×0.5 / ×2 | lognormal, GSD² 2.03 | -0.1 / +0.1 | 0.6 (Ecotoxicity, freshwater_organics) |
| Control and wiring, decentralized unit, at plant [RER] | 3.080e-04 p | ×0.872 / ×1.15 | lognormal, GSD² 1.15 | -0.1 / +0.1 | 1.9 (Resource use, minerals and metals) |
| Disposal, air filter, decentralized unit, 180-250 m3/h [CH] | 0.0151 p | ×0.872 / ×1.15 | lognormal, GSD² 1.15 | -0.1 / +0.1 | 0.1 (Climate change-Fossil) |
| Disposal, air filter, in exhaust air valve [CH] | 0.0226 p | ×0.872 / ×1.15 | lognormal, GSD² 1.15 | -0.0 / +0.0 | 0.0 (Climate change-Fossil) |
| Flexible duct, aluminum/PET, DN of 125, at plant [RER] | 0.00103 m | ×0.872 / ×1.15 | lognormal, GSD² 1.15 | -0.0 / +0.0 | 0.1 (Ecotoxicity, freshwater_organics) |
| Disposal, control and wiring, decentralized unit [CH] | 3.080e-04 p | ×0.872 / ×1.15 | lognormal, GSD² 1.15 | -0.0 / +0.0 | 0.1 (Ecotoxicity, freshwater_inorganics) |
| Disposal, flexible duct, aluminum/PET, DN of 125 [CH] | 0.00103 m | ×0.872 / ×1.15 | lognormal, GSD² 1.15 | -0.0 / +0.0 | 0.0 (Climate change-Fossil) |
Uncertainty analysis
Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.
Comparison with other data
No other location of this dataset in the graph.
Conclusions and limitations
GWP100 0.715 kg CO2 eq per m2a (95 % interval 0.6655–0.9373). Dominant contributors: Electricity, low voltage, at grid 49 %; Ventilation system, decentralized, 6 x 120 m3/h, steel ducts… 30 %; Ventilation equipment, decentralized, 180-250 m3/h, at plant 9 %; Silencer, steel, DN 125, at plant 5 %; Air filter, decentralized unit, 180-250 m3/h, at plant 2 %; Disposal, ventilation equipment, decentralized, 180-250 m3 1 %. Most sensitive: Electricity, low voltage, at grid [CH] (-6.0 / +6.8 %); Ventilation system, decentralized, 6 x 120 m3/h, steel ducts, without GHE [CH] (-3.9 / +4.4 %); Ventilation equipment, decentralized, 180-250 m3/h, at plant [RER] (-1.2 / +1.3 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.
Final control
| Item | Status | Detail |
|---|---|---|
| reference flow | PASS | production amount 1.0 m2a |
| closure: sum of direct contributions = dataset score (all 25 categories) | PASS | largest relative gap 4.0e-16 |
| independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | PASS | graph / published = 1; categories within ±5 %: 22/25 |
| every technosphere input of the EcoSpold delivery is in the graph | PASS | all present (bafu_links_check.py) |
| uncertainty declared on the direct exchanges | PASS | 17/17 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values |
| Monte Carlo 95 % interval contains the deterministic score | PASS | 0.715 in [0.6655, 0.9373] |
| time period declared | PASS | 2003-01/2003-12 |
| geography is a known location code | PASS | CH |
| sources cited | PASS | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them |
References
- Hässig, W., Primas, A. (2007) Ökologische Aspekte der Komfortlüftungen im Wohnbereich. Final report ecoinvent Data v2.0. Volume: 25. Swiss Centre for LCI, B+H. Dübendorf and Zürich, CH. Type: Measurement on site Source: CD-ROM First author: Hässig, W. Other authors: Primas, A. Year: 2007 Title of anthology: Final report ecoinvent Data v2.0 Place of publication: Dübendorf and Zürich, CH Publisher: … — published source; as declared by BAFU (not found in OpenAlex/Crossref)
- Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
- International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
- Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
- European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
- Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236
Annex — licence and terms of use
BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.
To suggest a correction or a dataset that does not exist yet, use Propose a dataset.