Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Cable, printer cable, without plugs, at plant [GLO], per 1 m. EF v3.1 climate change 0.351 kg CO2 eq (Monte Carlo 95 % interval 0.2706–0.749). Main contributors: Polyvinylchloride, at regional storage 35 %; Printed wiring board mounting plant 26 %; Copper, primary, at refinery 15 %; Electricity, medium voltage, production GLO, at grid 12 %; Extrusion, plastic pipes 4 %; Aluminium, primary, at plant 2 %. Status: final control passed.
Item Value
Dataset name Cable, printer cable, without plugs, at plant
Dataset UUID / graph id e7bf3741-ebb7-3557-adac-b4063ac626dc / activity:cable_printer_cable_without_plugs_at_plant__glo
Reference product, unit Cable, printer cable, without plugs, at plant, 1 m
Location GLO — The data describes a typical printer cable in 2006. The kind of printer cable is produced by international manufacturers and available all over the world. Therefore a global dataset is justifiable.
Time period 2023-01/2029-12
Category electronics / devices
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

This dataset can be applied to describe the production of a typical printer cable to connect to the desktop or laptop computer. The total weight of 1 m of printer cable is 0.072 kg (without the belonging plugs). The information for this dataset is based on weighing, measurements and analysis at EMPA Laboratories. In 2023, only production efforts data are updated. Furthermore, material and energy input are now represented by global inventory flows; UUID: e7bf3741-ebb7-3557-adac-b4063ac626dc

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 m of Cable, printer cable, without plugs, at plant (GLO). All results are given per unit of the reference flow.

System boundary

Describes the production of a typical printer cable (connector). Calculated per 1 m of printer cable. Included are the materials copper, PVC, and aluminium with their attributed manufacturing processes like wire drawing or extrusion. The infrastructure is calculated via the proxy “electronic component production plant”. Further inventoried are the electricity for the assembly of the connector, the fuel oil, propane and water input, the disposal of plastic and rubber parts, the VOC and methanol emissions created during the processing, plus the road and rail transportation for input materials from the regional storage to the production site. The accumulated hazardous waste is also reported.

Technology

The manufacturing process is represented through plastic extrusion (PVC), sheet rolling (aluminium), and wire drawing (copper).

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Polyvinylchloride, at regional storage technosphere RER 0.0525 kg lognormal, GSD² 1.33 — 35.2 ███████
Printed wiring board mounting plant technosphere GLO 1.4976e-08 p lognormal, GSD² 3.11 — 26.3 █████
Copper, primary, at refinery technosphere GLO 0.0196 kg lognormal, GSD² 1.33 — 15.0 ███
Electricity, medium voltage, production GLO, at grid technosphere GLO 0.074832 kWh lognormal, GSD² 1.33 — 12.3 ██
Extrusion, plastic pipes technosphere RER 0.0525 kg lognormal, GSD² 1.33 — 3.8 █
Aluminium, primary, at plant technosphere RER 9.0000e-04 kg lognormal, GSD² 1.33 — 2.3 ·
Wire drawing, copper technosphere RER 0.0196 kg lognormal, GSD² 1.33 — 2.1 ·
Disposal, plastics, mixture, 15.3% water, to municipal incineration technosphere CH 0.0018194 kg lognormal, GSD² 1.33 — 1.2 ·
Heat, heavy fuel oil, at industrial furnace 1MW technosphere RER 0.036046 MJ lognormal, GSD² 1.33 — 1.1 ·
Transport, freight, lorry, fleet average technosphere RER 0.0073 tkm lognormal, GSD² 2.12 — 0.4 ·
Disposal, hazardous waste, 25% water, to hazardous waste incineration technosphere CH 2.2065e-04 kg lognormal, GSD² 1.33 — 0.1 ·
Sheet rolling, aluminium technosphere RER 9.0000e-04 kg lognormal, GSD² 1.33 — 0.1 ·
Tap water, at user technosphere RER 1.452 kg lognormal, GSD² 1.33 — 0.1 ·
Transport, freight, rail technosphere RER 0.0146 tkm lognormal, GSD² 2.12 — 0.1 ·
Propane, butane, at refinery technosphere RER 1.3355e-05 kg lognormal, GSD² 1.33 — 0.0 ·
Methanol elementary air/Medium stack, <150 meters / Rural (<… 9.2903e-06 kg lognormal, GSD² 2.11 — 0.0 ·
Non-methane Volatile Organic Compounds elementary air/Medium stack, <150 meters / Rural (<… 6.9677e-06 kg lognormal, GSD² 2.11 — 0.0 ·

Data quality

0 of 17 direct exchanges carry a declared pedigree, 17 carry a distribution.

Field As declared by the publisher
Data generator / entry / validation data generator: Lugas Raka Adrianto, Maulana Permana Ajie, Didier Beloin-Saint-Pierre (EMPA); data entry: Lugas Raka Adrianto, Maulana Permana Ajie, Didier Beloin-Saint-Pierre (EMPA); validation (proof reading): Mischa Zschokke (CARBOTECH)
extrapolations see Geography and Technology
sampling procedure Weighing and measuring of materials. Literature for electricity consumption (assembly), emissions and waste.
production volume unknown
uncertainty adjustments see Geography and Technology
validation details Proof reading validation: Passed, Other validation: none, Validator: Mischa Zschokke, Company: Carbotech, Country: CH

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 m. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 0.01344 0.008688 0.0218 1.6
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.001401 9.422e-04 0.003155 1.89
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.3495 0.2694 0.7462 1.67
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 1.376e-04 9.992e-05 3.681e-04 1.9
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.351 0.2706 0.749 1.67
EF-particulate Matter Impact on human health disease incidence 3.363e-08 2.636e-08 7.615e-08 1.68
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 5.173 3.965 14.49 1.99
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 0.04295 0.03689 0.1255 1.88
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 5.216 4.013 14.54 1.99
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 7.769e-04 5.672e-04 0.001657 1.75
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 0.003717 0.00204 0.02344 3.59
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 0.009132 0.006396 0.01841 1.7
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.912e-09 1.112e-09 6.824e-09 2.46
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 1.223e-10 9.331e-11 3.971e-10 2.09
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 2.034e-09 1.268e-09 6.995e-09 2.34
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 1.863e-07 9.757e-08 6.630e-07 2.61
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 9.175e-09 4.210e-09 2.026e-08 2.24
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 1.955e-07 1.086e-07 6.674e-07 2.53
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 0.07799 0.03074 0.5488 4.31
Land use Soil quality index pt (soil quality index) 6.794 3.806 23.04 2.57
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 5.333e-08 2.839e-08 1.221e-07 2.13
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 0.002709 0.002087 0.004774 1.52
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 5.563 4.375 11.28 1.59
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 5.024e-05 3.669e-05 8.605e-05 1.52
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 0.09016 -214.1 108.1 —

Climate change 0.351 kg CO2 eq per m. Main contributors: Polyvinylchloride, at regional storage 35 %; Printed wiring board mounting plant 26 %; Copper, primary, at refinery 15 %; Electricity, medium voltage, production GLO, at grid 12 %; Extrusion, plastic pipes 4 %; Aluminium, primary, at plant 2 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Polyvinylchloride, at regional storage 35 %; Printed wiring board mounting plant 26 %; Copper, primary, at refinery 15 %; Electricity, medium voltage, production GLO, at grid 12 %; Extrusion, plastic pipes 4 %; Aluminium, primary, at plant 2 %. Most sensitive exchanges (Section 6.3): Printed wiring board mounting plant [GLO] (-17.6 / +53.6 %); Polyvinylchloride, at regional storage [RER] (-8.6 / +11.3 %); Copper, primary, at refinery [GLO] (-3.7 / +4.8 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 0.01344 0.01359 0.989
Climate change-Biogenic 0.001401 0.001401 1.000
Climate change-Fossil 0.3495 0.3495 1.000
Climate change-Land use and land use change 1.376e-04 1.376e-04 1.000
Climate change 0.351 0.351 1.000
EF-particulate Matter 3.363e-08 3.363e-08 1.000
Ecotoxicity, freshwater_inorganics 5.173 5.332 0.970
Ecotoxicity, freshwater_organics 0.04295 0.04268 1.006
Ecotoxicity, freshwater 5.216 5.372 0.971
Eutrophication marine 7.769e-04 7.769e-04 1.000
Eutrophication, freshwater 0.003717 0.003717 1.000
Eutrophication, terrestrial 0.009132 0.009268 0.985
Human toxicity, cancer_inorganics 1.912e-09 1.908e-09 1.002
Human toxicity, cancer_organics 1.223e-10 1.223e-10 1.000
Human toxicity, cancer 2.034e-09 2.031e-09 1.002
Human toxicity, non-cancer_inorganics 1.863e-07 1.861e-07 1.001
Human toxicity, non-cancer_organics 9.175e-09 9.175e-09 1.000
Human toxicity, non-cancer 1.955e-07 1.953e-07 1.001
Ionising radiation, human health 0.07799 0.07799 1.000
Land use 6.794 4.805 1.414
Ozone depletion 5.333e-08 5.333e-08 1.000
Photochemical ozone formation - human health 0.002709 0.002709 1.000
Resource use, fossils 5.563 5.564 1.000
Resource use, minerals and metals 5.024e-05 4.950e-05 1.015
Water use 0.09016 0.0924 0.976
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 0.351 kg CO2 eq; Ecological Scarcity
2021 total 2234 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Printed wiring board mounting plant [GLO] 1.498e-08 p ×0.329 / ×3.04 lognormal, GSD² 3.11 -17.6 / +53.6 135.1 (Land use)
Polyvinylchloride, at regional storage [RER] 0.0525 kg ×0.756 / ×1.32 lognormal, GSD² 1.33 -8.6 / +11.3 29.1 (Ozone depletion)
Copper, primary, at refinery [GLO] 0.0196 kg ×0.756 / ×1.32 lognormal, GSD² 1.33 -3.7 / +4.8 30.4 (Human toxicity, non-cancer_inorganics)
Electricity, medium voltage, production GLO, at grid [GLO] 0.07483 kWh ×0.756 / ×1.32 lognormal, GSD² 1.33 -3.0 / +4.0 9.9 (Climate change-Land use and land use change)
Extrusion, plastic pipes [RER] 0.0525 kg ×0.756 / ×1.32 lognormal, GSD² 1.33 -0.9 / +1.2 4.1 (Ionising radiation, human health)
Aluminium, primary, at plant [RER] 9.000e-04 kg ×0.756 / ×1.32 lognormal, GSD² 1.33 -0.6 / +0.7 2.7 (Climate change-Land use and land use change)
Wire drawing, copper [RER] 0.0196 kg ×0.756 / ×1.32 lognormal, GSD² 1.33 -0.5 / +0.7 1.5 (Ionising radiation, human health)
Disposal, plastics, mixture, 15.3% water, to municipal incineration [CH] 0.001819 kg ×0.756 / ×1.32 lognormal, GSD² 1.33 -0.3 / +0.4 0.4 (Climate change-Fossil)
Transport, freight, lorry, fleet average [RER] 0.0073 tkm ×0.479 / ×2.09 lognormal, GSD² 2.12 -0.2 / +0.4 4.2 (Climate change-Land use and land use change)
Heat, heavy fuel oil, at industrial furnace 1MW [RER] 0.03605 MJ ×0.756 / ×1.32 lognormal, GSD² 1.33 -0.3 / +0.3 0.3 (Climate change-Fossil)
Transport, freight, rail [RER] 0.0146 tkm ×0.479 / ×2.09 lognormal, GSD² 2.12 -0.0 / +0.1 0.3 (Ionising radiation, human health)
Disposal, hazardous waste, 25% water, to hazardous waste incineration [CH] 2.206e-04 kg ×0.756 / ×1.32 lognormal, GSD² 1.33 -0.0 / +0.0 0.0 (Ecotoxicity, freshwater_inorganics)
Sheet rolling, aluminium [RER] 9.000e-04 kg ×0.756 / ×1.32 lognormal, GSD² 1.33 -0.0 / +0.0 0.1 (Ionising radiation, human health)
Tap water, at user [RER] 1.452 kg ×0.756 / ×1.32 lognormal, GSD² 1.33 -0.0 / +0.0 6.1 (Water use)
Propane, butane, at refinery [RER] 1.336e-05 kg ×0.756 / ×1.32 lognormal, GSD² 1.33 -0.0 / +0.0 0.0 (Resource use, fossils)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 0.351 kg CO2 eq per m (95 % interval 0.2706–0.749). Dominant contributors: Polyvinylchloride, at regional storage 35 %; Printed wiring board mounting plant 26 %; Copper, primary, at refinery 15 %; Electricity, medium voltage, production GLO, at grid 12 %; Extrusion, plastic pipes 4 %; Aluminium, primary, at plant 2 %. Most sensitive: Printed wiring board mounting plant [GLO] (-17.6 / +53.6 %); Polyvinylchloride, at regional storage [RER] (-8.6 / +11.3 %); Copper, primary, at refinery [GLO] (-3.7 / +4.8 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 m
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 4.8e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 24/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 17/17 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 0.351 in [0.2706, 0.749]
time period declared PASS 2023-01/2029-12
geography is a known location code PASS GLO
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Raka Adrianto L. (2024) 2024 - LCI ICT sector - Raka Adrianto. Empa — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.

datasets/bafu/e7bf3741-ebb7-3557-adac-b4063ac626dc.txt · Last modified: by 127.0.0.1

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki