Table of Contents
Ventilation system, centralized, average for 2 m3/(h m2) — CH
Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData
Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Ventilation system, centralized, average for 2 m3/(h m2) [CH], per 1 m2. EF v3.1 climate change 17.76 kg CO2 eq (Monte Carlo 95 % interval 17.36–21.28). Main contributors: Ventilation system, various components, m2 15 %; Ventilation duct, steel, zinc coated, s= 0.75mm, at plant 14 %; Ventilation duct, steel, zinc coated, s= 0.62mm, at plant 9 %; Ventilation duct, steel, zinc coated, s= 0.87mm, at plant 8 %; Ventilation duct, steel, zinc coated, s= 1.0mm, at plant 6 %; Ventilation unit 13000 m3/h, w. circuit connected heat excha… 5 %. Status: final control passed.
| Item | Value |
|---|---|
| Dataset name | Ventilation system, centralized, average for 2 m3/(h m2) |
| Dataset UUID / graph id | e95dc8a0-6f85-3250-8b9f-59c2de7928f7 / activity:ventilation_system_centralized_average_for_2_m3_h_m2__ch |
| Reference product, unit | Ventilation system, centralized, average for 2 m3/(h m2), 1 m2 |
| Location | CH |
| Time period | 2014-01/2014-12 |
| Category | ventilation / production of components |
| Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 |
| Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) |
| Background database | BAFU 2026 v1 (graph bafuquery-db) |
| LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) |
| Status | final control passed |
| Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 |
Introduction
Production of a ventilation system for a building with a specific air flow rate of 2 m3/h per m2 heated gross floor area. The reference value of the inventory is 1 m2 heated gross floor area. The inventory is based on average data of 4 office buildings, 3 schools and 3 residential care homes with a total heated gross floor area of 61719 m2 and a total nominal air flow of 302190 m3/h, specific weight of the components: 5.61 kg/m2, including average components for air handling units, ducts including insulation, air valves, roof-hoods, dampers, fire dampers, silencers. The data represent a ductwork mainly made of galvanized steel and includes air handling units mainly with heat recovery and a nominal air flow rate of 5'000-20'000 m3/h per unit. No ground heat exchanger is included.; UUID: e95dc8a0-6f85-3250-8b9f-59c2de7928f7
This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.
Goal and scope
Function, functional unit and reference flow
Reference flow: 1 m2 of Ventilation system, centralized, average for 2 m3/(h m2) (CH). All results are given per unit of the reference flow.
System boundary
Materials used for the production. Energy use for the different production steps and for heating the production building. Transport of raw materials to the plant. Estimation for infrastructure of the production site included.
Technology
Typical technology, materials and components used for ventilation systems in commercial and public buildings
Link to the background database
Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).
LCIA method
EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.
Life cycle inventory
Inventory table
Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).
| Exchange | Type | Location / compartment | Amount | Unit | Uncertainty | Pedigree | GWP share (%) | Notes | |
|---|---|---|---|---|---|---|---|---|---|
| Ventilation system, various components, m2 | technosphere | CH | 1 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 15.1 | ███ | |
| Ventilation duct, steel, zinc coated, s= 0.75mm, at plant | technosphere | CH | 0.099793 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 14.1 | ███ | |
| Ventilation duct, steel, zinc coated, s= 0.62mm, at plant | technosphere | CH | 0.077357 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 8.8 | ██ | |
| Ventilation duct, steel, zinc coated, s= 0.87mm, at plant | technosphere | CH | 0.048431 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 7.7 | ██ | |
| Ventilation duct, steel, zinc coated, s= 1.0mm, at plant | technosphere | CH | 0.035074 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 6.3 | █ | |
| Ventilation unit 13000 m3/h, w. circuit connected heat exchanger, at plant | technosphere | CH | 6.1511e-05 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 5.2 | █ | |
| Ventilation unit 13000 m3/h, w. rotary heat exchanger, at plant | technosphere | CH | 4.5954e-05 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 4.6 | █ | |
| EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium foil, at plant | technosphere | CH | 0.083546 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 4.6 | █ | |
| Spiral-seam duct, steel, zinc coated, s= 0.5mm, at plant | technosphere | CH | 0.049692 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 4.2 | █ | |
| Ventilation duct, steel, zinc coated, s= 1.25mm, at plant | technosphere | CH | 0.014226 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 3.1 | █ | |
| Spiral-seam duct, steel, zinc coated, s= 0.6mm, at plant | technosphere | CH | 0.029293 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 2.9 | █ | |
| Ventilation unit 3500 m3/h, w. cross plate heat excanger, at plant | technosphere | CH | 6.7156e-05 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 2.7 | █ | |
| Thermal insulation, 30mm, 40kg/m3, reinforced alumium foil, at plant | technosphere | CH | 0.1157 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 2.6 | █ | |
| Ventilation unit 6700 m3/h, w. cross plate heat excanger, at plant | technosphere | CH | 3.6931e-05 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 2.4 | · | |
| Ventilation unit 6700 m3/h, w. circuit connected heat exchanger, at plant | technosphere | CH | 3.6276e-05 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 1.8 | · | |
| Silencer for ventilator unit 13000 m3/h, modular, at plant | technosphere | CH | 3.9266e-04 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 1.7 | · | |
| Ventilation unit 13000 m3/h, w. cross plate heat excanger, at plant | technosphere | CH | 1.3324e-05 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 1.5 | · | |
| Ventilation duct, steel, zinc coated, s= 1.5mm, at plant | technosphere | CH | 0.0052899 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 1.4 | · | |
| Ventilation unit 6700 m3/h, w. rotary heat exchanger, at plant | technosphere | CH | 2.1883e-05 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 1.3 | · | |
| EI 60 fire insulation, 70mm, 120kg/m3, reinforced alumium foil, at plant | technosphere | CH | 0.017045 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 1.2 | · | |
| Silencer for ventilator unit 6700 m3/h, modular, at plant, Device | technosphere | CH | 2.5694e-04 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.7 | · | |
| Ventilation duct, PE corrugated tube, DN 75, at plant | technosphere | RER | 0.11555 | m | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.7 | · | |
| Thermal insulation, 100mm, 40kg/m3, alumium cladding, at plant | technosphere | CH | 0.0070241 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.7 | · | |
| Ventilation duct, stainless steel, s= 1.0mm, at plant | technosphere | CH | 0.001794 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.5 | · | |
| Ventilation unit 1800 m3/h, w. cross plate heat excanger, at plant | technosphere | CH | 2.0348e-05 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.5 | · | |
| Ventilation duct, stainless steel, s= 1.25mm, at plant | technosphere | CH | 0.0013371 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.5 | · | |
| Ventilation duct, stainless steel, s= 1.5mm, at plant | technosphere | CH | 9.8826e-04 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.4 | · | |
| Ventilator unit 13000 m3/h, modular, w. filter, without silencer, at plant | technosphere | CH | 1.5246e-05 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.4 | · | |
| Thermal insulation, 30mm, 40kg/m3, stainless steel cladding, at plant | technosphere | CH | 0.0018184 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.3 | · | |
| Silencer for ventilator unit 3500 m3/h, modular, at plant | technosphere | CH | 1.4722e-04 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.3 | · | |
| Thermal insulation, 60mm, 40kg/m3, reinforced alumium foil, at plant | technosphere | CH | 0.0072389 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.2 | · | |
| Ventilator unit 3500 m3/h, modular, w. filter, without silencer, at plant | technosphere | CH | 2.2994e-05 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.2 | · | |
| Ventilation unit 3500 m3/h, w. circuit connected heat exchanger, at plant | technosphere | CH | 6.1795e-06 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.2 | · | |
| Ventilation duct, stainless steel, s= 0.87mm, at plant | technosphere | CH | 6.8290e-04 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.2 | · | |
| Thermal insulation, 60mm, 40kg/m3, stainless steel cladding, at plant | technosphere | CH | 8.2644e-04 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.2 | · | |
| Spiral-seam duct, steel, zinc coated, s= 0.8mm, at plant | technosphere | CH | 0.0012418 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.2 | · | |
| Silencer for ventilator unit 1800 m3/h, modular, at plant, Device | technosphere | CH | 6.4450e-05 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.1 | · | |
| Flexible duct, aluminum/PET, DN of 125, at plant | technosphere | RER | 0.019767 | m | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.1 | · | |
| Ventilation equipment, central, 600-1200 m3/h, at plant | technosphere | RER | 2.5856e-05 | p | lognormal, GSD² 1.26 | (3,4,1,1,1,5) | 0.1 | · | |
| Thermal insulation, 100mm, 40kg/m3, reinforced alumium foil, at plant | technosphere | CH | 0.0022137 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.1 | · | |
| Ventilation duct, stainless steel, s= 0.62mm, at plant | technosphere | CH | 4.6666e-04 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.1 | · | |
| Spiral-seam duct, stainless steel, s= 0.8mm, at plant | technosphere | CH | 2.9242e-04 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.1 | · | |
| Ventilation duct, stainless steel, s= 0.75mm, at plant | technosphere | CH | 9.1357e-05 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.0 | · | |
| Spiral-seam duct, stainless steel, s= 0.5mm, at plant | technosphere | CH | 1.1047e-04 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.0 | · | |
| Spiral-seam duct, steel, zinc coated, s= 1.0mm, at plant | technosphere | CH | 2.1812e-05 | m2 | lognormal, GSD² 1.24 | (2,4,1,1,1,5) | 0.0 | · |
Data quality
45 of 45 direct exchanges carry a declared pedigree, 45 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 2.36 · completeness 4.0 · temporal 1.0 · geographical 1.0 · technological 1.0 · sample size 5.0.
| Field | As declared by the publisher |
|---|---|
| Data generator / entry / validation | data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Alex Primas (HSLU) |
| extrapolations | none |
| sampling procedure | Data from different call of bids for ventilation system used. Data completed with information from literature and from manufacturers |
| production volume | na |
| uncertainty adjustments | none |
| time period comment | Amount of material investigated in 2013. Process information partly from 2003 to 2012 |
Data gaps, proxies and assumptions
None recorded.
Life cycle impact assessment (EF v3.1)
Per 1 m2. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.
| Impact category | Indicator | Unit | Result | 2.5 % | 97.5 % | GSD² |
|---|---|---|---|---|---|---|
| Acidification | Accumulated Exceedance (AE) | mol H+ eq | 0.2464 | 0.1605 | 0.4566 | 1.74 |
| Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 0.06491 | 0.04401 | 0.1394 | 1.76 |
| Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 17.69 | 17.25 | 21.2 | 1.11 |
| Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 0.008695 | 0.007132 | 0.01433 | 1.43 |
| Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 17.76 | 17.36 | 21.28 | 1.11 |
| EF-particulate Matter | Impact on human health | disease incidence | 2.702e-06 | 2.045e-06 | 4.462e-06 | 1.49 |
| Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 80.52 | 79.13 | 137.9 | 1.34 |
| Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 1.861 | 1.741 | 3.879 | 1.69 |
| Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 82.38 | 81.34 | 140.2 | 1.33 |
| Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | 0.01946 | 0.01741 | 0.02812 | 1.28 |
| Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | 0.009725 | 0.007337 | 0.04357 | 2.48 |
| Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | 0.9642 | 0.5691 | 1.877 | 1.87 |
| Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | 9.791e-09 | 9.725e-09 | 2.327e-08 | 1.54 |
| Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | 7.779e-09 | 6.755e-09 | 1.419e-08 | 1.45 |
| Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | 1.757e-08 | 1.794e-08 | 3.375e-08 | 1.38 |
| Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | 6.934e-07 | 6.172e-07 | 1.869e-06 | 1.72 |
| Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | 2.501e-08 | 1.800e-08 | 4.913e-08 | 1.67 |
| Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | 7.184e-07 | 6.425e-07 | 1.909e-06 | 1.7 |
| Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | 4.737 | 1.715 | 29.32 | 4.29 |
| Land use | Soil quality index | pt (soil quality index) | 89.34 | 86.77 | 144.7 | 1.3 |
| Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | 4.766e-07 | 4.230e-07 | 7.628e-07 | 1.34 |
| Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | 0.05304 | 0.0503 | 0.08285 | 1.29 |
| Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | 209.3 | 200.1 | 291.7 | 1.21 |
| Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | 3.915e-04 | -4.194e-04 | 0.001939 | — |
| Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | 2.256 | -4310 | 2109 | — |
Climate change 17.76 kg CO2 eq per m2. Main contributors: Ventilation system, various components, m2 15 %; Ventilation duct, steel, zinc coated, s= 0.75mm, at plant 14 %; Ventilation duct, steel, zinc coated, s= 0.62mm, at plant 9 %; Ventilation duct, steel, zinc coated, s= 0.87mm, at plant 8 %; Ventilation duct, steel, zinc coated, s= 1.0mm, at plant 6 %; Ventilation unit 13000 m3/h, w. circuit connected heat excha… 5 %.
Interpretation
Significant issues
Direct exchanges dominating climate change: Ventilation system, various components, m2 15 %; Ventilation duct, steel, zinc coated, s= 0.75mm, at plant 14 %; Ventilation duct, steel, zinc coated, s= 0.62mm, at plant 9 %; Ventilation duct, steel, zinc coated, s= 0.87mm, at plant 8 %; Ventilation duct, steel, zinc coated, s= 1.0mm, at plant 6 %; Ventilation unit 13000 m3/h, w. circuit connected heat excha… 5 %. Most sensitive exchanges (Section 6.3): Ventilation system, various components, m2 [CH] (-2.9 / +3.6 %); Ventilation duct, steel, zinc coated, s= 0.75mm, at plant [CH] (-2.7 / +3.3 %); Ventilation duct, steel, zinc coated, s= 0.62mm, at plant [CH] (-1.7 / +2.1 %).
Independent recalculation
Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):
| Category | Graph | Published | Graph / published |
|---|---|---|---|
| Acidification | 0.2464 | 0.2579 | 0.955 |
| Climate change-Biogenic | 0.06491 | 0.06491 | 1.000 |
| Climate change-Fossil | 17.69 | 17.69 | 1.000 |
| Climate change-Land use and land use change | 0.008695 | 0.008695 | 1.000 |
| Climate change | 17.76 | 17.76 | 1.000 |
| EF-particulate Matter | 2.702e-06 | 2.702e-06 | 1.000 |
| Ecotoxicity, freshwater_inorganics | 80.52 | 81.05 | 0.993 |
| Ecotoxicity, freshwater_organics | 1.861 | 1.789 | 1.040 |
| Ecotoxicity, freshwater | 82.38 | 82.74 | 0.996 |
| Eutrophication marine | 0.01946 | 0.01946 | 1.000 |
| Eutrophication, freshwater | 0.009725 | 0.009725 | 1.000 |
| Eutrophication, terrestrial | 0.9642 | 0.9678 | 0.996 |
| Human toxicity, cancer_inorganics | 9.791e-09 | 9.728e-09 | 1.007 |
| Human toxicity, cancer_organics | 7.779e-09 | 7.779e-09 | 1.000 |
| Human toxicity, cancer | 1.757e-08 | 1.751e-08 | 1.004 |
| Human toxicity, non-cancer_inorganics | 6.934e-07 | 6.911e-07 | 1.003 |
| Human toxicity, non-cancer_organics | 2.501e-08 | 2.500e-08 | 1.000 |
| Human toxicity, non-cancer | 7.184e-07 | 7.161e-07 | 1.003 |
| Ionising radiation, human health | 4.737 | 4.737 | 1.000 |
| Land use | 89.34 | 75.04 | 1.191 |
| Ozone depletion | 4.766e-07 | 4.766e-07 | 1.000 |
| Photochemical ozone formation - human health | 0.05304 | 0.05304 | 1.000 |
| Resource use, fossils | 209.3 | 209.4 | 1.000 |
| Resource use, minerals and metals | 3.915e-04 | 3.849e-04 | 1.017 |
| Water use | 2.256 | 2.433 | 0.927 |
| Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | |||
| Also published by BAFU for this dataset: IPCC 2021 GWP100 17.76 kg CO2 eq; Ecological Scarcity | |||
| 2021 total 4.32e+04 UBP. |
Sensitivity check
One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.
| Exchange | Base | Low / high | Range | Δ GWP100 (%) | Δ other categories (max %) |
|---|---|---|---|---|---|
| Ventilation system, various components, m2 [CH] | 1 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -2.9 / +3.6 | 4.0 (Climate change-Biogenic) |
| Ventilation duct, steel, zinc coated, s= 0.75mm, at plant [CH] | 0.09979 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -2.7 / +3.3 | 4.9 (Eutrophication, terrestrial) |
| Ventilation duct, steel, zinc coated, s= 0.62mm, at plant [CH] | 0.07736 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -1.7 / +2.1 | 3.7 (Eutrophication, terrestrial) |
| Ventilation duct, steel, zinc coated, s= 0.87mm, at plant [CH] | 0.04843 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -1.5 / +1.8 | 2.4 (Eutrophication, terrestrial) |
| Ventilation duct, steel, zinc coated, s= 1.0mm, at plant [CH] | 0.03507 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -1.2 / +1.5 | 1.8 (Eutrophication, terrestrial) |
| Ventilation unit 13000 m3/h, w. circuit connected heat exchanger, at plant [CH] | 6.151e-05 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -1.1 / +1.3 | 4.1 (Eutrophication, freshwater) |
| Ventilation unit 13000 m3/h, w. rotary heat exchanger, at plant [CH] | 4.595e-05 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.9 / +1.2 | 2.3 (Resource use, minerals and metals) |
| EI 30 fire insulation, 50mm, 120kg/m3, reinforced alumium foil, at plant [CH] | 0.08355 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.9 / +1.1 | 4.3 (Ecotoxicity, freshwater_organics) |
| Spiral-seam duct, steel, zinc coated, s= 0.5mm, at plant [CH] | 0.04969 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.8 / +1.0 | 2.0 (Eutrophication, terrestrial) |
| Ventilation duct, steel, zinc coated, s= 1.25mm, at plant [CH] | 0.01423 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.6 / +0.7 | 0.8 (Climate change-Land use and land use change) |
| Ventilation unit 3500 m3/h, w. cross plate heat excanger, at plant [CH] | 6.716e-05 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.5 / +0.7 | 1.0 (Eutrophication, freshwater) |
| Spiral-seam duct, steel, zinc coated, s= 0.6mm, at plant [CH] | 0.02929 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.5 / +0.7 | 1.2 (Eutrophication, terrestrial) |
| Ventilation unit 6700 m3/h, w. cross plate heat excanger, at plant [CH] | 3.693e-05 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.5 / +0.6 | 1.0 (Eutrophication, freshwater) |
| Thermal insulation, 30mm, 40kg/m3, reinforced alumium foil, at plant [CH] | 0.1157 m2 | ×0.81 / ×1.23 | lognormal, GSD² 1.24 | -0.5 / +0.6 | 1.5 (Ecotoxicity, freshwater_organics) |
| Ventilation unit 6700 m3/h, w. circuit connected heat exchanger, at plant [CH] | 3.628e-05 p | ×0.797 / ×1.25 | lognormal, GSD² 1.26 | -0.4 / +0.5 | 1.3 (Eutrophication, freshwater) |
Uncertainty analysis
Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.
Comparison with other data
No other location of this dataset in the graph.
Conclusions and limitations
GWP100 17.76 kg CO2 eq per m2 (95 % interval 17.36–21.28). Dominant contributors: Ventilation system, various components, m2 15 %; Ventilation duct, steel, zinc coated, s= 0.75mm, at plant 14 %; Ventilation duct, steel, zinc coated, s= 0.62mm, at plant 9 %; Ventilation duct, steel, zinc coated, s= 0.87mm, at plant 8 %; Ventilation duct, steel, zinc coated, s= 1.0mm, at plant 6 %; Ventilation unit 13000 m3/h, w. circuit connected heat excha… 5 %. Most sensitive: Ventilation system, various components, m2 [CH] (-2.9 / +3.6 %); Ventilation duct, steel, zinc coated, s= 0.75mm, at plant [CH] (-2.7 / +3.3 %); Ventilation duct, steel, zinc coated, s= 0.62mm, at plant [CH] (-1.7 / +2.1 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.
Final control
| Item | Status | Detail |
|---|---|---|
| reference flow | PASS | production amount 1.0 m2 |
| closure: sum of direct contributions = dataset score (all 25 categories) | PASS | largest relative gap 4.2e-16 |
| independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) | PASS | graph / published = 1; categories within ±5 %: 23/25 |
| every technosphere input of the EcoSpold delivery is in the graph | PASS | all present (bafu_links_check.py) |
| uncertainty declared on the direct exchanges | PASS | 45/45 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values |
| Monte Carlo 95 % interval contains the deterministic score | PASS | 17.76 in [17.36, 21.28] |
| time period declared | PASS | 2014-01/2014-12 |
| geography is a known location code | PASS | CH |
| sources cited | PASS | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them |
References
- Klingler M., Kasser U., Savi D., Primas A., Stettler Y., Gujer P. (2014) Ökobilanzdaten für Lüftungs- und Wärmeanlagen. Schlussbericht, BFE. Bundesamt für Energie (BFE). Bern. Type: Separate publication Source: Report First author: Klingler M. Other authors: Kasser U., Savi D., Primas A., Stettler Y., Gujer P. Year: 2014 Title of anthology: Schlussbericht, BFE Place of publication: Bern Publisher:… — published source; as declared by BAFU (not found in OpenAlex/Crossref)
- Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
- International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
- Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
- European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
- Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236
Annex — licence and terms of use
BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.
To suggest a correction or a dataset that does not exist yet, use Propose a dataset.