Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Electricity, residential, by combustion of hydrogen using CHP, allocated by exergy, distributed by truck, produced by Electrolysis, SOEC with steam input using electricity from grid [CH], per 1 kWh. EF v3.1 climate change 0.5984 kg CO2 eq (Monte Carlo 95 % interval 0.3531–1.567). Main contributors: Hydrogen supply, distributed by truck, produced by Electroly… 84 %; High pressure hydrogen Type I storage tank production 14 %; Hydrogen supply, distributed by truck, produced by Electroly… 1 %. Status: final control passed.
| Item | Value |
|---|---|
| Dataset name | Electricity, residential, by combustion of hydrogen using CHP, allocated by exergy, distributed by truck, produced by Electrolysis, SOEC with steam input using electricity from grid |
| Dataset UUID / graph id | ec876ea1-f748-3899-b9e7-d3b8f5929d95 / activity:electricity_residential_by_combustion_of_hydrogen_using_chp_allocated_by_exergy_distributed_by_truck_produced___73099021 |
| Reference product, unit | Electricity, residential, by combustion of hydrogen using CHP, allocated by exergy, distributed by truck, produced by Electrolysis, SOEC with steam input using electricity from grid, 1 kWh |
| Location | CH |
| Time period | 2024-01/2024-01 |
| Category | heat / synthetic\transformation |
| Source database | BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1 |
| Publisher | Swiss Federal Office for the Environment (FOEN/BAFU) |
| Background database | BAFU 2026 v1 (graph bafuquery-db) |
| LCIA method | EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix) |
| Status | final control passed |
| Documented by | tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17 |
Introduction
This dataset represents the supply of 1 kilowatt hour of electricity in a residence, by hydrogen combustion in a CHP. The hydrogen is produced by Electrolysis, SOEC with steam input, with electricity from grid as feedstock. Electricity conversion efficiency [% LHV input]: 39.4%. LHV [kWh/kg]: 33.33. Market price [Euro/MJ]: 0.03. Synthesis efficiency [% LHV input]: 0%. Total cap. Input-related [kW]: 443.9. CO2 biogenic share [%]: 0%. Power [kW]: 200. Lifetime [years]: 19.51. Annual operation [hours]: 4100. Allocation factor: 0.92. On-site storage loss [%]: 1.26. Use loss [%]: 0.5. For more information, refer to: Sacchi, R. and Bauer, C. LCA of Power-to-X processes and applications in the residential sector. Paul Scherrer Institut, 2023. Source: Sacchi, R. and Bauer, C. LCA of Power-to-X processes and applications in the residential sector. Paul Scherrer Institut, 2023. UUID: ec876ea1-f748-3899-b9e7-d3b8f5929d95
This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.
Goal and scope
Function, functional unit and reference flow
Reference flow: 1 kWh of Electricity, residential, by combustion of hydrogen using CHP, allocated by exergy, distributed by truck, produced by Electrolysis, SOEC with steam input using electricity from grid (CH). All results are given per unit of the reference flow.
System boundary
—
Technology
—
Link to the background database
Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).
LCIA method
EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.
Life cycle inventory
Inventory table
Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).
| Exchange | Type | Location / compartment | Amount | Unit | Uncertainty | Pedigree | GWP share (%) | Notes | |
|---|---|---|---|---|---|---|---|---|---|
| Hydrogen supply, distributed by truck, produced by Electrolysis, SOEC with steam… | technosphere | CH | 0.06981 | kg | lognormal, GSD² 1.38 | — | 84.1 | █████████████████ | |
| High pressure hydrogen Type I storage tank production | technosphere | GLO | 1.6610e-05 | p | lognormal, GSD² 3.14 | — | 14.0 | ███ | |
| Hydrogen supply, distributed by truck, produced by Electrolysis, SOEC with steam… | technosphere | CH | 0.001233 | kg | lognormal, GSD² 1.38 | — | 1.5 | · | |
| Cogen unit 160kWe, common components for heat+electricity | technosphere | RER | 2.5820e-08 | p | lognormal, GSD² 3.14 | — | 0.3 | · | |
| Cogen unit 160kWe, components for heat only | technosphere | RER | 2.5820e-08 | p | lognormal, GSD² 3.14 | — | 0.1 | · | |
| Cogen unit 160kWe, components for electricity only | technosphere | RER | 2.5820e-08 | p | lognormal, GSD² 3.14 | — | 0.0 | · | |
| Disposal, used mineral oil, 10% water, to hazardous waste incineration | technosphere | CH | 1.0420e-07 | kg | none declared: tdc-doc default ±50 % | — | 0.0 | · | |
| Lubricating oil, at plant | technosphere | RER | 1.0420e-07 | kg | lognormal, GSD² 1.38 | — | 0.0 | · | |
| Transport, freight, lorry, 16t-32t gross weight, fleet average | technosphere | CH | 3.4390e-09 | tkm | lognormal, GSD² 2.21 | — | 0.0 | · | |
| Transport, freight, rail, electricity with shunting | technosphere | CH | 3.4390e-09 | tkm | lognormal, GSD² 2.21 | — | 0.0 | · | |
| Nitrogen Oxides, CH | elementary | air/Unknown [CH] | 2.5000e-05 | kg | lognormal, GSD² 1.68 | — | 0.0 | · | |
| Water vapour | elementary | air/Aircraft cruise height | 6.2830e-04 | m3 | lognormal, GSD² 1.38 | — | 0.0 | · | |
| Hydrogen | elementary | air/Unknown | 0.001233 | kg | none declared: tdc-doc default ±50 % | — | 0.0 | · |
Data quality
0 of 13 direct exchanges carry a declared pedigree, 11 carry a distribution.
| Field | As declared by the publisher |
|---|---|
| Data generator / entry / validation | data generator: Romain Sacchi (PSI); data entry: Romain Sacchi (PSI); validation (proof reading): Romain Sacchi (PSI) |
| sampling procedure | Sampling procedure: Literature data |
| validation details | Proof reading validation: Passed, Other validation: none, Validator: Rolf Frischknecht, Telephone: 0041 44 940 61 91, E-mail: frischknecht@treeze.ch, Company: treeze, Country: CH |
Data gaps, proxies and assumptions
| Item | Class | Value used | Reason | Effect |
|---|---|---|---|---|
| 2 exchange(s) without declared uncertainty | uncertainty | fixed in the Monte Carlo | the publisher declares no distribution | ±50 % in the sensitivity check (Section 6.3) |
Life cycle impact assessment (EF v3.1)
Per 1 kWh. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.
| Impact category | Indicator | Unit | Result | 2.5 % | 97.5 % | GSD² |
|---|---|---|---|---|---|---|
| Acidification | Accumulated Exceedance (AE) | mol H+ eq | 0.00148 | 9.111e-04 | 0.004055 | 2.14 |
| Climate change-Biogenic | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 0.009046 | 0.004158 | 0.02578 | 2.55 |
| Climate change-Fossil | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 0.5881 | 0.3468 | 1.532 | 2.12 |
| Climate change-Land use and land use change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 0.00126 | 6.486e-04 | 0.003284 | 2.3 |
| Climate change | Radiative forcing as Global Warming Potential (GWP100) | kg CO2 eq | 0.5984 | 0.3531 | 1.567 | 2.12 |
| EF-particulate Matter | Impact on human health | disease incidence | 2.437e-08 | 1.536e-08 | 6.908e-08 | 2.13 |
| Ecotoxicity, freshwater_inorganics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 1.879 | 1.164 | 6.776 | 2.42 |
| Ecotoxicity, freshwater_organics | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 0.05091 | 0.036 | 0.1682 | 2.27 |
| Ecotoxicity, freshwater | Comparative Toxic Unit for ecosystems (CTUe) | CTUe | 1.93 | 1.216 | 7.027 | 2.4 |
| Eutrophication marine | Fraction of nutrients reaching marine end compartment (N) | kg N eq | 4.494e-04 | 2.877e-04 | 0.001171 | 2.04 |
| Eutrophication, freshwater | Fraction of nutrients reaching freshwater end compartment (P) | kg P eq | 3.717e-04 | 1.738e-04 | 0.002324 | 3.59 |
| Eutrophication, terrestrial | Accumulated Exceedance (AE) | mol N eq | 0.00351 | 0.002351 | 0.008949 | 1.99 |
| Human toxicity, cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | 1.652e-10 | 1.307e-10 | 6.224e-10 | 2.24 |
| Human toxicity, cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | 2.017e-10 | 1.140e-10 | 5.595e-10 | 2.28 |
| Human toxicity, cancer | Comparative Toxic Unit for human (CTUh) | CTUh | 3.670e-10 | 2.516e-10 | 1.140e-09 | 2.16 |
| Human toxicity, non-cancer_inorganics | Comparative Toxic Unit for human (CTUh) | CTUh | 8.656e-09 | 6.400e-09 | 3.717e-08 | 2.43 |
| Human toxicity, non-cancer_organics | Comparative Toxic Unit for human (CTUh) | CTUh | 4.709e-10 | 2.618e-10 | 1.791e-09 | 2.67 |
| Human toxicity, non-cancer | Comparative Toxic Unit for human (CTUh) | CTUh | 9.126e-09 | 6.740e-09 | 3.918e-08 | 2.42 |
| Ionising radiation, human health | Human exposure efficiency relative to U235 | kBq U235 eq | 2.381 | 0.6317 | 17.5 | 5.33 |
| Land use | Soil quality index | pt (soil quality index) | 5.798 | 2.95 | 17.06 | 2.41 |
| Ozone depletion | Ozone Depletion Potential (ODP) | kg CFC-11 eq | 4.328e-08 | 2.238e-08 | 1.228e-07 | 2.35 |
| Photochemical ozone formation - human health | Tropospheric ozone concentration increase | kg NMVOC eq | 0.001436 | 9.724e-04 | 0.003953 | 2.03 |
| Resource use, fossils | Abiotic resource depletion fossil fuels (ADP-fossil) | MJ | 27.08 | 14.01 | 71.9 | 2.37 |
| Resource use, minerals and metals | Abiotic resource depletion (ADP ultimate reserve) | kg Sb eq | 4.418e-06 | 2.138e-06 | 1.653e-05 | 2.84 |
| Water use | User deprivation potential (deprivation-weighted water consumption) | m3 world eq deprived | 0.2455 | -982.7 | 606 | — |
Climate change 0.5984 kg CO2 eq per kWh. Main contributors: Hydrogen supply, distributed by truck, produced by Electroly… 84 %; High pressure hydrogen Type I storage tank production 14 %; Hydrogen supply, distributed by truck, produced by Electroly… 1 %.
Interpretation
Significant issues
Direct exchanges dominating climate change: Hydrogen supply, distributed by truck, produced by Electroly… 84 %; High pressure hydrogen Type I storage tank production 14 %; Hydrogen supply, distributed by truck, produced by Electroly… 1 %. Most sensitive exchanges (Section 6.3): Hydrogen supply, distributed by truck, produced by Electrolysis, SOEC with steam input usi… (-22.8 / +31.4 %); High pressure hydrogen Type I storage tank production [GLO] (-9.4 / +28.9 %); Hydrogen supply, distributed by truck, produced by Electrolysis, SOEC with steam input usi… (-0.4 / +0.6 %).
Independent recalculation
Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh:
| Category | Graph | Published | Graph / published |
|---|---|---|---|
| Acidification | 0.00148 | 0.001707 | 0.867 |
| Climate change-Biogenic | 0.009046 | 0.009046 | 1.000 |
| Climate change-Fossil | 0.5881 | 0.5881 | 1.000 |
| Climate change-Land use and land use change | 0.00126 | 0.00126 | 1.000 |
| Climate change | 0.5984 | 0.5984 | 1.000 |
| EF-particulate Matter | 2.437e-08 | 2.437e-08 | 1.000 |
| Ecotoxicity, freshwater_inorganics | 1.879 | 1.966 | 0.955 |
| Ecotoxicity, freshwater_organics | 0.05091 | 0.05034 | 1.011 |
| Ecotoxicity, freshwater | 1.93 | 2.015 | 0.958 |
| Eutrophication marine | 4.494e-04 | 4.483e-04 | 1.002 |
| Eutrophication, freshwater | 3.717e-04 | 3.717e-04 | 1.000 |
| Eutrophication, terrestrial | 0.00351 | 0.003886 | 0.903 |
| Human toxicity, cancer_inorganics | 1.652e-10 | 1.605e-10 | 1.030 |
| Human toxicity, cancer_organics | 2.017e-10 | 2.017e-10 | 1.000 |
| Human toxicity, cancer | 3.670e-10 | 3.622e-10 | 1.013 |
| Human toxicity, non-cancer_inorganics | 8.656e-09 | 8.427e-09 | 1.027 |
| Human toxicity, non-cancer_organics | 4.709e-10 | 4.708e-10 | 1.000 |
| Human toxicity, non-cancer | 9.126e-09 | 8.897e-09 | 1.026 |
| Ionising radiation, human health | 2.381 | 2.381 | 1.000 |
| Land use | 5.798 | 4.683 | 1.238 |
| Ozone depletion | 4.328e-08 | 4.328e-08 | 1.000 |
| Photochemical ozone formation - human health | 0.001436 | 0.001436 | 1.000 |
| Resource use, fossils | 27.08 | 27.08 | 1.000 |
| Resource use, minerals and metals | 4.418e-06 | 4.364e-06 | 1.012 |
| Water use | 0.2455 | 0.2763 | 0.889 |
| Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like. | |||
| Also published by BAFU for this dataset: IPCC 2021 GWP100 0.5981 kg CO2 eq; Ecological Scarcity | |||
| 2021 total 2014 UBP. |
Sensitivity check
One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.
| Exchange | Base | Low / high | Range | Δ GWP100 (%) | Δ other categories (max %) |
|---|---|---|---|---|---|
| Hydrogen supply, distributed by truck, produced by Electrolysis, SOEC with steam input usi… | 0.06981 kg | ×0.728 / ×1.37 | lognormal, GSD² 1.38 | -22.8 / +31.4 | 36.3 (Ionising radiation, human health) |
| High pressure hydrogen Type I storage tank production [GLO] | 1.661e-05 p | ×0.326 / ×3.07 | lognormal, GSD² 3.14 | -9.4 / +28.9 | 72.5 (Human toxicity, cancer_inorganics) |
| Hydrogen supply, distributed by truck, produced by Electrolysis, SOEC with steam input usi… | 0.001233 kg | ×0.728 / ×1.37 | lognormal, GSD² 1.38 | -0.4 / +0.6 | 0.6 (Ionising radiation, human health) |
| Cogen unit 160kWe, common components for heat+electricity [RER] | 2.582e-08 p | ×0.326 / ×3.07 | lognormal, GSD² 3.14 | -0.2 / +0.7 | 3.0 (Human toxicity, non-cancer_organics) |
| Cogen unit 160kWe, components for heat only [RER] | 2.582e-08 p | ×0.326 / ×3.07 | lognormal, GSD² 3.14 | -0.0 / +0.1 | 0.3 (Human toxicity, cancer_inorganics) |
| Cogen unit 160kWe, components for electricity only [RER] | 2.582e-08 p | ×0.326 / ×3.07 | lognormal, GSD² 3.14 | -0.0 / +0.1 | 0.6 (Human toxicity, non-cancer_organics) |
| Disposal, used mineral oil, 10% water, to hazardous waste incineration [CH] | 1.042e-07 kg | ×0.5 / ×1.5 | none declared: tdc-doc default ±50 % | -0.0 / +0.0 | 0.0 (Climate change-Fossil) |
| Lubricating oil, at plant [RER] | 1.042e-07 kg | ×0.728 / ×1.37 | lognormal, GSD² 1.38 | -0.0 / +0.0 | 0.0 (Ecotoxicity, freshwater_organics) |
| Transport, freight, lorry, 16t-32t gross weight, fleet average [CH] | 3.439e-09 tkm | ×0.46 / ×2.17 | lognormal, GSD² 2.21 | -0.0 / +0.0 | 0.0 (Photochemical ozone formation - human health) |
| Transport, freight, rail, electricity with shunting [CH] | 3.439e-09 tkm | ×0.46 / ×2.17 | lognormal, GSD² 2.21 | -0.0 / +0.0 | 0.0 (Land use) |
| Nitrogen Oxides, CH [air/Unknown [CH]] | 2.500e-05 kg | ×0.603 / ×1.66 | lognormal, GSD² 1.68 | -0.0 / +0.0 | 1.5 (Eutrophication, terrestrial) |
Uncertainty analysis
Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.
Comparison with other data
No other location of this dataset in the graph.
Conclusions and limitations
GWP100 0.5984 kg CO2 eq per kWh (95 % interval 0.3531–1.567). Dominant contributors: Hydrogen supply, distributed by truck, produced by Electroly… 84 %; High pressure hydrogen Type I storage tank production 14 %; Hydrogen supply, distributed by truck, produced by Electroly… 1 %. Most sensitive: Hydrogen supply, distributed by truck, produced by Electrolysis, SOEC with steam input usi… (-22.8 / +31.4 %); High pressure hydrogen Type I storage tank production [GLO] (-9.4 / +28.9 %); Hydrogen supply, distributed by truck, produced by Electrolysis, SOEC with steam input usi… (-0.4 / +0.6 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.
Final control
| Item | Status | Detail |
|---|---|---|
| reference flow | PASS | production amount 1.0 kWh |
| closure: sum of direct contributions = dataset score (all 25 categories) | PASS | largest relative gap 2.6e-16 |
| independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) — published per MJ, converted ×3.6 to per kWh (climate change) | PASS | graph / published = 1; categories within ±5 %: 21/25 |
| every technosphere input of the EcoSpold delivery is in the graph | PASS | all present (bafu_links_check.py) |
| uncertainty declared on the direct exchanges | PASS | 11/13 exchanges carry a distribution (85 %); the others enter the Monte Carlo as fixed values |
| Monte Carlo 95 % interval contains the deterministic score | PASS | 0.5984 in [0.3531, 1.567] |
| time period declared | PASS | 2024-01/2024-01 |
| geography is a known location code | PASS | CH |
| sources cited | PASS | 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them |
References
- Report — source; as declared by BAFU (not found in OpenAlex/Crossref)
- Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
- International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
- Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
- European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
- Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236
Annex — licence and terms of use
BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.