OpenData Wiki

Dataset documentation and review before publication

User Tools

Site Tools


datasets:bafu:ee4e6217-09f5-3e62-b94a-1d169c650f69

Ventilation system, Geschäftshaus C, Esslingen, special components — CH

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Ventilation system, Geschäftshaus C, Esslingen, special components [CH], per 1 p. EF v3.1 climate change 300.9 kg CO2 eq (Monte Carlo 95 % interval 258.1–511.7). Main contributors: Cable, connector for computer, without plugs, at plant 38 %; Fan, at plant 31 %; Medium density fibreboard, uncoated, at plant 17 %; Acrylonitrile-butadiene-styrene copolymer, ABS, at plant 7 %; Transformer, low voltage use, at plant 4 %; Steel, converter, unalloyed, at plant 2 %. Status: final control passed.
Item Value
Dataset name Ventilation system, Geschäftshaus C, Esslingen, special components
Dataset UUID / graph id ee4e6217-09f5-3e62-b94a-1d169c650f69 / activity:ventilation_system_geschäftshaus_c_esslingen_special_components__ch
Reference product, unit Ventilation system, Geschäftshaus C, Esslingen, special components, 1 p
Location CH
Time period 2014-01/2014-12
Category ventilation / production of components
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

Production of special components of a ventilation system for an office building with offices only (no kitchen, restaurant or car park). The inventory is based on a building with a total heated gross floor area of 2621 m2 and a total nominal air flow of 4000 m3/h, total weight of the components: 121 kg/Unit, building with a specific air flow rate of 1.5 m3/h per m2 heated gross floor area. Data from call of bid including decental ventilation units between circulation area and offices. Components including fans, wiring and transformer but without surrounding light-weight wall.; UUID: ee4e6217-09f5-3e62-b94a-1d169c650f69

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 p of Ventilation system, Geschäftshaus C, Esslingen, special components (CH). All results are given per unit of the reference flow.

System boundary

Materials used for the production. Energy use for the different production steps and for heating the production building. Transport of raw materials to the plant. Estimation for infrastructure of the production site included.

Technology

Technology, materials and components used for ventilation systems in commercial and public buildings

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Cable, connector for computer, without plugs, at plant technosphere GLO 338.36 m lognormal, GSD² 1.34 (3,4,1,1,3,5) 38.4 ████████
Fan, at plant technosphere GLO 10 kg lognormal, GSD² 1.34 (3,4,1,1,3,5) 30.8 ██████
Medium density fibreboard, uncoated, at plant technosphere RER 0.098077 m3 lognormal, GSD² 1.26 (3,4,1,1,1,5) 16.9 ███
Acrylonitrile-butadiene-styrene copolymer, ABS, at plant technosphere RER 4.5 kg lognormal, GSD² 1.26 (3,4,1,1,1,5) 6.8 █
Transformer, low voltage use, at plant technosphere GLO 3.6 kg lognormal, GSD² 1.26 (3,4,1,1,1,5) 3.6 █
Steel, converter, unalloyed, at plant technosphere RER 2.52 kg lognormal, GSD² 1.26 (3,4,1,1,1,5) 2.0 ·
Sheet rolling, steel technosphere RER 4 kg lognormal, GSD² 1.26 (3,4,1,1,1,5) 0.5 ·
Zinc coating, coils technosphere RER 0.34 m2 lognormal, GSD² 1.26 (3,4,1,1,1,5) 0.5 ·
Steel, electric, un- and low-alloyed, at plant technosphere RER 1.48 kg lognormal, GSD² 1.26 (3,4,1,1,1,5) 0.3 ·
Transport, freight, lorry, 16t-32t gross weight, fleet average technosphere CH 4.25 tkm lognormal, GSD² 2.14 (4,5,1,1,1,5) 0.2 ·
Transport, freight, rail technosphere RER 18.6 tkm lognormal, GSD² 2.14 (4,5,1,1,1,5) 0.1 ·

Data quality

11 of 11 direct exchanges carry a declared pedigree, 11 carry a distribution. Mean declared pedigree (1 = best, 5 = worst): reliability 3.18 · completeness 4.18 · temporal 1.0 · geographical 1.0 · technological 1.36 · sample size 5.0.

Field As declared by the publisher
Data generator / entry / validation data generator: Alex Primas (HSLU); data entry: Alex Primas (HSLU); validation (proof reading): Alex Primas (HSLU)
extrapolations none
sampling procedure Data from call of bids for a ventilation system of a specific building used. Data completed with information from literature and from manufacturers
production volume na
uncertainty adjustments none
time period comment Amount of material investigated in 2013. Process information partly from 2003 to 2012

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 5.687 4.113 9.453 1.54
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 1.004 0.6696 2.531 1.98
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 299.7 257.2 509.9 1.41
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.1381 0.1089 0.273 1.61
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 300.9 258.1 511.7 1.41
EF-particulate Matter Impact on human health disease incidence 2.226e-05 1.979e-05 3.978e-05 1.42
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 2772 2360 7481 1.75
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 72.47 61.47 152.1 1.58
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 2844 2431 7603 1.74
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 0.4466 0.3741 0.8626 1.57
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 1.514 0.8613 10.16 3.58
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 5.651 4.69 10.09 1.47
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 7.274e-07 4.638e-07 2.514e-06 2.31
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 6.511e-07 4.274e-07 1.481e-06 1.87
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 1.378e-06 1.077e-06 3.393e-06 1.78
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 6.966e-05 4.254e-05 2.378e-04 2.49
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 3.648e-06 1.872e-06 7.924e-06 2.08
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 7.331e-05 4.616e-05 2.421e-04 2.42
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 62.95 23.98 434.8 4.38
Land use Soil quality index pt (soil quality index) 1.071e+04 8828 1.733e+04 1.38
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 2.190e-05 1.620e-05 4.298e-05 1.64
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 1.789 1.536 3.045 1.42
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 5180 4523 8758 1.39
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 0.04979 0.03175 0.1064 1.84
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 44.55 -1.290e+05 6.081e+04 —

Climate change 300.9 kg CO2 eq per p. Main contributors: Cable, connector for computer, without plugs, at plant 38 %; Fan, at plant 31 %; Medium density fibreboard, uncoated, at plant 17 %; Acrylonitrile-butadiene-styrene copolymer, ABS, at plant 7 %; Transformer, low voltage use, at plant 4 %; Steel, converter, unalloyed, at plant 2 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Cable, connector for computer, without plugs, at plant 38 %; Fan, at plant 31 %; Medium density fibreboard, uncoated, at plant 17 %; Acrylonitrile-butadiene-styrene copolymer, ABS, at plant 7 %; Transformer, low voltage use, at plant 4 %; Steel, converter, unalloyed, at plant 2 %. Most sensitive exchanges (Section 6.3): Cable, connector for computer, without plugs, at plant [GLO] (-9.6 / +12.7 %); Fan, at plant [GLO] (-7.7 / +10.2 %); Medium density fibreboard, uncoated, at plant [RER] (-3.4 / +4.3 %).

Independent recalculation

The publisher publishes no LCIA result for this dataset; the closure check of Section 7 is the recalculation test.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Cable, connector for computer, without plugs, at plant [GLO] 338.4 m ×0.751 / ×1.33 lognormal, GSD² 1.34 -9.6 / +12.7 29.8 (Human toxicity, non-cancer_inorganics)
Fan, at plant [GLO] 10 kg ×0.751 / ×1.33 lognormal, GSD² 1.34 -7.7 / +10.2 20.4 (Resource use, minerals and metals)
Medium density fibreboard, uncoated, at plant [RER] 0.09808 m3 ×0.797 / ×1.25 lognormal, GSD² 1.26 -3.4 / +4.3 22.5 (Human toxicity, cancer_organics)
Acrylonitrile-butadiene-styrene copolymer, ABS, at plant [RER] 4.5 kg ×0.797 / ×1.25 lognormal, GSD² 1.26 -1.4 / +1.7 2.1 (Resource use, fossils)
Transformer, low voltage use, at plant [GLO] 3.6 kg ×0.797 / ×1.25 lognormal, GSD² 1.26 -0.7 / +0.9 5.3 (Ecotoxicity, freshwater_organics)
Steel, converter, unalloyed, at plant [RER] 2.52 kg ×0.797 / ×1.25 lognormal, GSD² 1.26 -0.4 / +0.5 0.5 (Climate change-Fossil)
Transport, freight, lorry, 16t-32t gross weight, fleet average [CH] 4.25 tkm ×0.474 / ×2.11 lognormal, GSD² 2.14 -0.1 / +0.3 0.3 (Photochemical ozone formation - human health)
Sheet rolling, steel [RER] 4 kg ×0.797 / ×1.25 lognormal, GSD² 1.26 -0.1 / +0.1 0.2 (Water use)
Zinc coating, coils [RER] 0.34 m2 ×0.797 / ×1.25 lognormal, GSD² 1.26 -0.1 / +0.1 2.3 (Eutrophication, terrestrial)
Transport, freight, rail [RER] 18.6 tkm ×0.474 / ×2.11 lognormal, GSD² 2.14 -0.1 / +0.1 0.5 (Ionising radiation, human health)
Steel, electric, un- and low-alloyed, at plant [RER] 1.48 kg ×0.797 / ×1.25 lognormal, GSD² 1.26 -0.1 / +0.1 0.2 (Ionising radiation, human health)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 300.9 kg CO2 eq per p (95 % interval 258.1–511.7). Dominant contributors: Cable, connector for computer, without plugs, at plant 38 %; Fan, at plant 31 %; Medium density fibreboard, uncoated, at plant 17 %; Acrylonitrile-butadiene-styrene copolymer, ABS, at plant 7 %; Transformer, low voltage use, at plant 4 %; Steel, converter, unalloyed, at plant 2 %. Most sensitive: Cable, connector for computer, without plugs, at plant [GLO] (-9.6 / +12.7 %); Fan, at plant [GLO] (-7.7 / +10.2 %); Medium density fibreboard, uncoated, at plant [RER] (-3.4 / +4.3 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 p
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 3.1e-16
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 11/11 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 300.9 in [258.1, 511.7]
time period declared PASS 2014-01/2014-12
geography is a known location code PASS CH
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Klingler M., Kasser U., Savi D., Primas A., Stettler Y., Gujer P. (2014) Ökobilanzdaten für Lüftungs- und Wärmeanlagen. Schlussbericht, BFE. Bundesamt für Energie (BFE). Bern. Type: Separate publication Source: Report First author: Klingler M. Other authors: Kasser U., Savi D., Primas A., Stettler Y., Gujer P. Year: 2014 Title of anthology: Schlussbericht, BFE Place of publication: Bern Publisher:… — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.

datasets/bafu/ee4e6217-09f5-3e62-b94a-1d169c650f69.txt · Last modified: by 127.0.0.1