OpenData Wiki

Dataset documentation and review before publication

User Tools

Site Tools


datasets:bafu:ef0274ee-89af-3f6f-8046-1c6a62ef198f

Tablet, average, at plant — GLO

Dataset documentation and final control (tdc-doc, imported mode)
Open this dataset in OpenData

Abstract. BAFU 2026 v1 (Swiss Federal Office for the Environment). Dataset Tablet, average, at plant [GLO], per 1 p. EF v3.1 climate change 50.35 kg CO2 eq (Monte Carlo 95 % interval 46.66–65.66). Main contributors: Wafer, fabricated, for integrated circuit, logic type, at pl… 36 %; LED module, at plant 20 %; Wafer, fabricated, for integrated circuit, memory type, at p… 13 %; Printed wiring board, surface mounted, unspec., Pb free, at … 12 %; Electricity, medium voltage, production RAS, at grid 5 %; Power supply unit, at plant 4 %. Status: final control passed.
Item Value
Dataset name Tablet, average, at plant
Dataset UUID / graph id ef0274ee-89af-3f6f-8046-1c6a62ef198f / activity:tablet_average_at_plant__glo
Reference product, unit Tablet, average, at plant, 1 p
Location GLO — Data for global average for tablets
Time period 2023-01/2029-12
Category electronics / devices
Source database BAFU 2026 v1 (Swiss Federal Office for the Environment), version 2026 v1
Publisher Swiss Federal Office for the Environment (FOEN/BAFU)
Background database BAFU 2026 v1 (graph bafuquery-db)
LCIA method EF v3.1, consensus-flow-list implementation, 25 categories (bw2calc on the graph matrix)
Status final control passed
Documented by tdc-doc, imported mode (graph recalculation, Monte Carlo, final control), 2026-11-17

Introduction

The data set represents the production of tablet with defined technical specifications; UUID: ef0274ee-89af-3f6f-8046-1c6a62ef198f

This report documents an imported dataset: its inventory and metadata come from the publisher, not from the tdc pipeline. tdc-doc recomputes it on the graph, checks it (Section 7), and reports it in the ISO 14044 / BAFU DQR v2.1 structure used for tdc's own datasets. Sections that only apply to datasets built by tdc (stoichiometry, energy model, literature excerpts) are replaced by what the publisher declares.

Goal and scope

Function, functional unit and reference flow

Reference flow: 1 p of Tablet, average, at plant (GLO). All results are given per unit of the reference flow.

System boundary

The dataset for average tablets, represented here as iPad Gen 2 with the weight of ~500 gr, is obtained from the LCA studies of Ahmadi Achachlouei et al., 2015; Teehan and Kandikar, 2013; and Hischier et al., 2015. The referred studies connect the lab-based data with the LCA database, i.e., Ecoinvent. This means that data is performed on the level of individual components (i.e., on the level of ICs, resistors, etc.) to build more precise inventory models for the device. The modeled tablet has a flash storage capacity of 256 GB and RAM capacity of 3 GB. According to the industry technology for IC tablets, up to 6 stacked dies can be integrated in a single package to optimize density and performance. In the modeling, the area of wafer/die is assumed to be ~10.2 cm2 to represent total wafer logic area according to the literature.

Technology

The tablet has a processing unit, flash storage, RAM, and other connectivity features for standard tablets.

Native BAFU dataset: exchanges as delivered in EcoSpold v1, linked by the graph migration (graphlca.load).

LCIA method

EF v3.1, characterisation only (no normalisation or weighting), consensus-flow-list implementation of the 25 categories, with regionalised factors where the flow carries a place.

Life cycle inventory

Inventory table

Direct exchanges per reference flow, ordered by their share of climate change. Uncertainty: the distribution declared on the graph edge (BAFU: lognormal from the pedigree matrix). Pedigree: the scores the publisher declares (BAFU: reliability, completeness, temporal, geographical, technological, sample size; PEF DQR otherwise).

Exchange Type Location / compartment Amount Unit Uncertainty Pedigree GWP share (%) Notes
Wafer, fabricated, for integrated circuit, logic type, at plant technosphere GLO 0.00102 m2 lognormal, GSD² 1.25 — 36.2 ███████
LED module, at plant technosphere GLO 0.145 kg lognormal, GSD² 1.25 — 19.8 ████
Wafer, fabricated, for integrated circuit, memory type, at plant technosphere GLO 7.7000e-04 m2 lognormal, GSD² 1.25 — 13.0 ███
Printed wiring board, surface mounted, unspec., Pb free, at plant technosphere GLO 0.039 kg lognormal, GSD² 1.25 — 12.5 ██
Electricity, medium voltage, production RAS, at grid technosphere RAS 3.5278 kWh lognormal, GSD² 1.25 — 5.1 █
Power supply unit, at plant technosphere GLO 0.09 p lognormal, GSD² 1.25 — 4.1 █
Battery, Li-ion, NMC111, rechargeable, prismatic technosphere GLO 0.135 kg lognormal, GSD² 1.25 — 3.1 █
Charger, for tablet, at plant technosphere GLO 1 p lognormal, GSD² 1.25 — 1.4 ·
Aluminium, production mix, at plant technosphere RER 0.14 kg lognormal, GSD² 1.25 — 1.3 ·
Integrated circuit, IC, logic type, at plant technosphere GLO 0.001 kg lognormal, GSD² 1.25 — 1.2 ·
Disposal, laptop computer, to WEEE treatment technosphere CH 0.18 p lognormal, GSD² 1.36 — 0.9 ·
Integrated circuit, IC, memory type, at plant technosphere GLO 0.001 kg lognormal, GSD² 1.25 — 0.7 ·
Flat glass, coated, at plant technosphere RER 0.109 kg lognormal, GSD² 1.25 — 0.2 ·
Transport, transoceanic freight ship technosphere OCE 10.7 tkm lognormal, GSD² 2.07 — 0.1 ·
Sheet rolling, aluminium technosphere RER 0.14 kg lognormal, GSD² 1.25 — 0.1 ·
Acrylonitrile-butadiene-styrene copolymer, ABS, at plant technosphere RER 0.009 kg lognormal, GSD² 1.25 — 0.1 ·
Polyurethane, rigid foam, at plant technosphere RER 0.009 kg lognormal, GSD² 1.25 — 0.1 ·
Copper, primary, at refinery technosphere GLO 0.013 kg lognormal, GSD² 1.25 — 0.1 ·
Steel, low-alloyed, at plant technosphere RER 0.013 kg lognormal, GSD² 1.25 — 0.1 ·
Transport, freight, lorry, fleet average technosphere RER 0.0505 tkm lognormal, GSD² 2.07 — 0.0 ·
Sheet rolling, steel technosphere RER 0.013 kg lognormal, GSD² 1.25 — 0.0 ·
Sheet rolling, copper technosphere RER 0.013 kg lognormal, GSD² 1.25 — 0.0 ·
Transport, freight, rail technosphere RER 0.101 tkm lognormal, GSD² 2.07 — 0.0 ·

Data quality

0 of 23 direct exchanges carry a declared pedigree, 23 carry a distribution.

Field As declared by the publisher
Data generator / entry / validation data generator: Lugas Raka Adrianto, Maulana Permana Ajie, Didier Beloin-Saint-Pierre (EMPA); data entry: Lugas Raka Adrianto, Maulana Permana Ajie, Didier Beloin-Saint-Pierre (EMPA); validation (proof reading): Mischa Zschokke (CARBOTECH)
extrapolations Average technology
sampling procedure Literature & own estimations
production volume unknown
uncertainty adjustments none
validation details Proof reading validation: Passed, Other validation: none, Validator: Mischa Zschokke, Company: Carbotech, Country: CH

Data gaps, proxies and assumptions

None recorded.

Life cycle impact assessment (EF v3.1)

Per 1 p. The 95 % interval and GSD² come from the Monte Carlo of Section 6.4.

Impact category Indicator Unit Result 2.5 % 97.5 % GSD²
Acidification Accumulated Exceedance (AE) mol H+ eq 0.2211 0.1993 0.3121 1.25
Climate change-Biogenic Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.207 0.1177 0.5618 2.23
Climate change-Fossil Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 50.12 46.39 65.14 1.19
Climate change-Land use and land use change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 0.01641 0.01395 0.02639 1.38
Climate change Radiative forcing as Global Warming Potential (GWP100) kg CO2 eq 50.35 46.66 65.66 1.19
EF-particulate Matter Impact on human health disease incidence 1.373e-06 1.361e-06 2.302e-06 1.3
Ecotoxicity, freshwater_inorganics Comparative Toxic Unit for ecosystems (CTUe) CTUe 364.5 341.2 723.8 1.47
Ecotoxicity, freshwater_organics Comparative Toxic Unit for ecosystems (CTUe) CTUe 22.18 17.48 35.81 1.45
Ecotoxicity, freshwater Comparative Toxic Unit for ecosystems (CTUe) CTUe 386.7 364.1 750.4 1.45
Eutrophication marine Fraction of nutrients reaching marine end compartment (N) kg N eq 0.07326 0.06412 0.1171 1.36
Eutrophication, freshwater Fraction of nutrients reaching freshwater end compartment (P) kg P eq 0.08426 0.05826 0.4955 2.92
Eutrophication, terrestrial Accumulated Exceedance (AE) mol N eq 0.4021 0.3774 0.638 1.31
Human toxicity, cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 5.295e-08 4.634e-08 1.444e-07 1.77
Human toxicity, cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 1.589e-08 1.359e-08 2.451e-08 1.36
Human toxicity, cancer Comparative Toxic Unit for human (CTUh) CTUh 6.884e-08 6.335e-08 1.604e-07 1.61
Human toxicity, non-cancer_inorganics Comparative Toxic Unit for human (CTUh) CTUh 3.236e-06 2.742e-06 8.684e-06 1.86
Human toxicity, non-cancer_organics Comparative Toxic Unit for human (CTUh) CTUh 1.159e-06 6.469e-07 2.414e-06 1.92
Human toxicity, non-cancer Comparative Toxic Unit for human (CTUh) CTUh 4.395e-06 3.688e-06 1.001e-05 1.7
Ionising radiation, human health Human exposure efficiency relative to U235 kBq U235 eq 11.01 3.406 72.55 4.85
Land use Soil quality index pt (soil quality index) 301 261.7 514.5 1.43
Ozone depletion Ozone Depletion Potential (ODP) kg CFC-11 eq 7.009e-06 5.281e-06 1.080e-05 1.45
Photochemical ozone formation - human health Tropospheric ozone concentration increase kg NMVOC eq 0.1367 0.1319 0.2116 1.27
Resource use, fossils Abiotic resource depletion fossil fuels (ADP-fossil) MJ 635.7 579.1 949.8 1.29
Resource use, minerals and metals Abiotic resource depletion (ADP ultimate reserve) kg Sb eq 0.008991 0.006965 0.01322 1.39
Water use User deprivation potential (deprivation-weighted water consumption) m3 world eq deprived 10.32 -1.375e+04 7116 —

Climate change 50.35 kg CO2 eq per p. Main contributors: Wafer, fabricated, for integrated circuit, logic type, at pl… 36 %; LED module, at plant 20 %; Wafer, fabricated, for integrated circuit, memory type, at p… 13 %; Printed wiring board, surface mounted, unspec., Pb free, at … 12 %; Electricity, medium voltage, production RAS, at grid 5 %; Power supply unit, at plant 4 %.

Interpretation

Significant issues

Direct exchanges dominating climate change: Wafer, fabricated, for integrated circuit, logic type, at pl… 36 %; LED module, at plant 20 %; Wafer, fabricated, for integrated circuit, memory type, at p… 13 %; Printed wiring board, surface mounted, unspec., Pb free, at … 12 %; Electricity, medium voltage, production RAS, at grid 5 %; Power supply unit, at plant 4 %. Most sensitive exchanges (Section 6.3): Wafer, fabricated, for integrated circuit, logic type, at plant [GLO] (-7.1 / +8.8 %); LED module, at plant [GLO] (-3.9 / +4.8 %); Wafer, fabricated, for integrated circuit, memory type, at plant [GLO] (-2.5 / +3.2 %).

Independent recalculation

Graph result against BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026):

Category Graph Published Graph / published
Acidification 0.2211 0.2791 0.792
Climate change-Biogenic 0.207 0.207 1.000
Climate change-Fossil 50.12 50.12 1.000
Climate change-Land use and land use change 0.01641 0.01641 1.000
Climate change 50.35 50.35 1.000
EF-particulate Matter 1.373e-06 1.373e-06 1.000
Ecotoxicity, freshwater_inorganics 364.5 372.4 0.979
Ecotoxicity, freshwater_organics 22.18 19.63 1.130
Ecotoxicity, freshwater 386.7 389.4 0.993
Eutrophication marine 0.07326 0.07326 1.000
Eutrophication, freshwater 0.08426 0.08426 1.000
Eutrophication, terrestrial 0.4021 0.421 0.955
Human toxicity, cancer_inorganics 5.295e-08 5.272e-08 1.004
Human toxicity, cancer_organics 1.589e-08 1.589e-08 1.000
Human toxicity, cancer 6.884e-08 6.862e-08 1.003
Human toxicity, non-cancer_inorganics 3.236e-06 3.222e-06 1.004
Human toxicity, non-cancer_organics 1.159e-06 1.159e-06 1.000
Human toxicity, non-cancer 4.395e-06 4.381e-06 1.003
Ionising radiation, human health 11.01 11.01 1.000
Land use 301 242.7 1.240
Ozone depletion 7.009e-06 7.009e-06 1.000
Photochemical ozone formation - human health 0.1367 0.1367 1.000
Resource use, fossils 635.7 635.8 1.000
Resource use, minerals and metals 0.008991 0.00897 1.002
Water use 10.32 11.31 0.912
Over all BAFU datasets, climate change agrees with the published table for 98.1 % of them within ±5 % (median ×1.000). Systematic differences are expected where the graph characterises differently from BAFU's table: regionalised factors (acidification, terrestrial eutrophication, land use, water use, by the flow's place) and the metal resource factors; these categories: Acidification median ×0.81 (16 % within ±5 %); Eutrophication, terrestrial median ×0.93 (37 % within ±5 %); Land use median ×1.23 (6 % within ±5 %); Resource use, minerals and metals median ×1.04 (52 % within ±5 %); Water use median ×0.75 (11 % within ±5 %). BAFU's table is per its own unit (electricity per MJ, cars per m, crops per m2), converted here, and carries the organics and inorganics sub-indicators of freshwater ecotoxicity in each other's column (primary copper: 99.7 % of its ecotoxicity under 'organics'); they are compared like with like.
Also published by BAFU for this dataset: IPCC 2021 GWP100 50.34 kg CO2 eq; Ecological Scarcity
2021 total 1.308e+05 UBP.

Sensitivity check

One at a time on each direct exchange, over its declared 95 % range (±50 % when none is declared, the tdc-doc default for an assumption without a range). The supply chain behind each input is held at its mean.

Exchange Base Low / high Range Δ GWP100 (%) Δ other categories (max %)
Wafer, fabricated, for integrated circuit, logic type, at plant [GLO] 0.00102 m2 ×0.804 / ×1.24 lognormal, GSD² 1.25 -7.1 / +8.8 11.6 (Ozone depletion)
LED module, at plant [GLO] 0.145 kg ×0.804 / ×1.24 lognormal, GSD² 1.25 -3.9 / +4.8 23.0 (Human toxicity, non-cancer_organics)
Wafer, fabricated, for integrated circuit, memory type, at plant [GLO] 7.700e-04 m2 ×0.804 / ×1.24 lognormal, GSD² 1.25 -2.5 / +3.2 8.6 (Ozone depletion)
Printed wiring board, surface mounted, unspec., Pb free, at plant [GLO] 0.039 kg ×0.804 / ×1.24 lognormal, GSD² 1.25 -2.4 / +3.0 13.8 (Resource use, minerals and metals)
Electricity, medium voltage, production RAS, at grid [RAS] 3.528 kWh ×0.804 / ×1.24 lognormal, GSD² 1.25 -1.0 / +1.2 1.2 (Climate change-Fossil)
Power supply unit, at plant [GLO] 0.09 p ×0.804 / ×1.24 lognormal, GSD² 1.25 -0.8 / +1.0 2.1 (Photochemical ozone formation - human health)
Battery, Li-ion, NMC111, rechargeable, prismatic [GLO] 0.135 kg ×0.804 / ×1.24 lognormal, GSD² 1.25 -0.6 / +0.7 5.8 (Acidification)
Charger, for tablet, at plant [GLO] 1 p ×0.804 / ×1.24 lognormal, GSD² 1.25 -0.3 / +0.3 2.4 (Resource use, minerals and metals)
Aluminium, production mix, at plant [RER] 0.14 kg ×0.804 / ×1.24 lognormal, GSD² 1.25 -0.3 / +0.3 1.4 (Climate change-Land use and land use change)
Disposal, laptop computer, to WEEE treatment [CH] 0.18 p ×0.74 / ×1.35 lognormal, GSD² 1.36 -0.2 / +0.3 0.5 (Ecotoxicity, freshwater_inorganics)
Integrated circuit, IC, logic type, at plant [GLO] 0.001 kg ×0.804 / ×1.24 lognormal, GSD² 1.25 -0.2 / +0.3 1.7 (Resource use, minerals and metals)
Integrated circuit, IC, memory type, at plant [GLO] 0.001 kg ×0.804 / ×1.24 lognormal, GSD² 1.25 -0.1 / +0.2 1.2 (Resource use, minerals and metals)
Transport, transoceanic freight ship [OCE] 10.7 tkm ×0.49 / ×2.04 lognormal, GSD² 2.07 -0.1 / +0.2 1.7 (Eutrophication, terrestrial)
Flat glass, coated, at plant [RER] 0.109 kg ×0.804 / ×1.24 lognormal, GSD² 1.25 -0.0 / +0.1 0.2 (EF-particulate Matter)
Sheet rolling, aluminium [RER] 0.14 kg ×0.804 / ×1.24 lognormal, GSD² 1.25 -0.0 / +0.0 0.1 (Ionising radiation, human health)

Uncertainty analysis

Monte Carlo over the whole supply chain: 1000 draws (seed 42, computed 2026-11-17), every exchange of the database that carries a distribution resampled at each draw, one adjoint solve per category per draw. Exchanges without a distribution enter as fixed values (Section 4.3). Results in Section 5.

Comparison with other data

No other location of this dataset in the graph.

Conclusions and limitations

GWP100 50.35 kg CO2 eq per p (95 % interval 46.66–65.66). Dominant contributors: Wafer, fabricated, for integrated circuit, logic type, at pl… 36 %; LED module, at plant 20 %; Wafer, fabricated, for integrated circuit, memory type, at p… 13 %; Printed wiring board, surface mounted, unspec., Pb free, at … 12 %; Electricity, medium voltage, production RAS, at grid 5 %; Power supply unit, at plant 4 %. Most sensitive: Wafer, fabricated, for integrated circuit, logic type, at plant [GLO] (-7.1 / +8.8 %); LED module, at plant [GLO] (-3.9 / +4.8 %); Wafer, fabricated, for integrated circuit, memory type, at plant [GLO] (-2.5 / +3.2 %). final control passed. The documentation relies on the publisher's metadata; this report is not a critical review in the sense of ISO 14044 clause 6.

Final control

Item Status Detail
reference flow PASS production amount 1.0 p
closure: sum of direct contributions = dataset score (all 25 categories) PASS largest relative gap 4.9e-16
independent recalculation vs BAFU 2026 v1 published EF 3.1 results (LCIA Results.xlsx, June 2026) (climate change) PASS graph / published = 1; categories within ±5 %: 21/25
every technosphere input of the EcoSpold delivery is in the graph PASS all present (bafu_links_check.py)
uncertainty declared on the direct exchanges PASS 23/23 exchanges carry a distribution (100 %); the others enter the Monte Carlo as fixed values
Monte Carlo 95 % interval contains the deterministic score PASS 50.35 in [46.66, 65.66]
time period declared PASS 2023-01/2029-12
geography is a known location code PASS GLO
sources cited PASS 2 reference(s), of which 1 dataset source(s); 0 resolved to a bibliographic record (DOI or Crossref/OpenAlex match), the others kept as the publisher declares them

References

  1. Raka Adrianto L. (2024) 2024 - LCI ICT sector - Raka Adrianto. Empa — published source; as declared by BAFU (not found in OpenAlex/Crossref)
  2. Life Cycle Inventory database of the Swiss Federal Administration, BAFU:2026 — database; dataset citation
  3. International Organization for Standardization (2006). ISO 14044:2006 Environmental management — Life cycle assessment — Requirements and guidelines (incl. Amd 1:2017, Amd 2:2020). Geneva.
  4. Frischknecht R. (2023). FOEN LCI data — Data quality requirements (DQR) v2.1. treeze Ltd. on behalf of the Swiss Federal Office for the Environment (FOEN/BAFU), Uster / Bern. (tdc-doc method reference; title, version and year to verify against the user's copy)
  5. European Commission, Joint Research Centre (2022). Environmental Footprint (EF) reference package 3.1. Ispra.
  6. Mutel C. (2017). Brightway: An open source framework for Life Cycle Assessment. Journal of Open Source Software 2(12), 236. https://doi.org/10.21105/joss.00236

Annex — licence and terms of use

BAFU:2026 Terms of Use - free use, processing and reuse of the data (including in LCA studies and calculators); the data may not be sold, resold or distributed as a database; modifications must be documented and shared under equivalent terms; credit required.


To suggest a correction or a dataset that does not exist yet, use Propose a dataset.

datasets/bafu/ef0274ee-89af-3f6f-8046-1c6a62ef198f.txt · Last modified: by 127.0.0.1

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki